摘要
文章介绍橡胶膜密封干式煤气柜的结构,针对在密封橡胶膜打折部位出现泄漏的现象,通过试漏、调平、检修及实际数据测量,分析出泄漏的主要原因是密封橡胶膜直径尺寸不合理,造成内膜易出现打折.最后提出了有效的处理措施。
The paper introduces the structure of the rubber sealing fihn for dry Gas Holder, in order to prevent from leakage on the folds of rubber sealing film, through leakage checking, leveling, maintenance and the actual data measuring, the mainly leakage reason is unreasonable diameter size of the sealing film,w hich cause folds on the inner film. Finally, the effective treatment measures are put forward.
出处
《广东化工》
CAS
2016年第5期145-147,共3页
Guangdong Chemical Industry
关键词
干式煤气柜
橡胶膜
泄漏
密封
dry gas holder
rubber sealing film
leakage: sealing