多机头冷水机组串联满液式换热器内水温分布的校核计算

Verifying calculation of water temperature distribution of series flooded heat exchangers in multiple compressors chiller unit
下载PDF
导出
摘要 当多机头冷水机组串联满液式换热器流程数量大于1时,至少1台换热器内存在水温分段现象。通常设计时未考虑该现象对机组性能的影响。采用分段计算的方法对双机头机组换热器内的水温分布进行了校核计算。结果表明,计算压比较设计压比分别偏离了4.9%和-6.42%,为压缩机、节流孔板的优化设计提供了依据。测试发现机组能效提高了2.26%。 When the flow number of series flooded heat exchangers in multiple compressors chiller unit is more than one,water temperature segmentation exits in one heat exchanger at least.Its influence on unit performance is not considered when designing the system.Verifies the water temperature distribution of the heat exchanger in double compressors chiller unit with the method of segmentation calculation.The results show that the calculation pressure ratios are changed +4.9% and-6.42% separately,compared with the design pressure ratio,providing the evidence for optimal design of compressor and throttle orifice.Test result shows that the unit efficiency increases by 2.26%.
出处 《暖通空调》 北大核心 2016年第3期62-65,共4页 Heating Ventilating & Air Conditioning
关键词 多机头冷水机组 串联满液式换热器 设计优化 分段计算 校核计算 multiple compressors chiller unit series flooded heat exchanger design optimization segmentation calculation verifying calculation
  • 相关文献

参考文献9

二级参考文献19

  • 1黄建恩,冯伟.一种螺杆式制冷机组能耗计算模型[J].暖通空调,2007,37(4):121-126. 被引量:4
  • 2元伟伟,蒋彦龙.风力发电冷却技术[J].世界科技研究与发展,2007,29(2):80-85. 被引量:10
  • 3天津大学化工原理教研室.化工原理[M].天津:天津大学科学技术出版社,1989.156.
  • 4YU F W, CHAN Kwok-tai. Electricity end-use characteristics of air-cooled chillers in hotels in Hong Kong[ J]. Building and Environment, 2005,40(1) :143 - 151.
  • 5LEE W S, LIN L C. Optimal chiller loading by particle swarm algorithm tbr reducing energy consumption [ J ]. Applied Thermal Engineering,2009, 29 ( 8/9 ) : 1730 - 1734.
  • 6Y U F W, C HAN Kwok-tai. Improved condenser design and condenser-fan operation for air-cooled chillers[ J ]. Applied Energy,2006,83 (6) : 628 - 648.
  • 7KIM Y S, KIM K S. Simplified energy prediction method accounting for part-load performance of chiller[ J]. Building and Environment, 2007,42(1 ) :507 - 515.
  • 8LEE T S, LU W C. An evaluation of empirically-based models for predicting energy performance of vapor-compression water chillers [ J ]. Applied Energy,2010,87 ( 11 ) :3486 - 3493.
  • 9GAN A I, KLEIN S A, REINDL D T. Analysis of refrigerator/freezer appliances having dual refrigeration cycles [ J ]. ASHRAE Transactions, 2000,106(2) :185 - 191.
  • 10MANSKE K A, KLEIN S A, REINDL D T. Load sharing strategies in multiple compressor refrigeration systems [ J ]. ASHRAE Transactions, 2002,108 ( 1 ) :327 - 333.