摘要 肝癌是一种常见的恶性肿瘤,其预后较差,病死率较高。受呼吸动度影响,肝癌的摆位误差较大,肝癌图像引导放疗是将放疗机与影像设备结合在一起,监测和校正治疗时由于器官运动和摆位不确定造成的误差,从而提高放疗的精确性。 Hepatocellular carcinoma is a common malignant tumor, which has a poor prognosis and a high mortality rate. Under the influence of respiratory motion, the position error of liver cancer is relatively high. The image-guided radiotherapy is a combination of radiotherapy and imaging device, which can detect and correct the error caused by the movement of the organs and the position of the pendulum to improve the accuracy of radiotherapy.
出处 《肿瘤研究与临床》 CAS 2016年第2期140-144,共5页 Cancer Research and Clinic
关键词 肝肿瘤 放射疗法 图像引导 图像配准 摆位误差 Liver neoplasms Radiotherapy,image-guided Image registration Setup error
  • 相关文献

参考文献32

  • 1Torre LA, Bray F, Siegel RL, et al. Global cancer statistics, 2012 [J ]. CA Cancer J Clin, 2015, 65 (2) : 87-108. DOI: 10.3322/caac.21262.
  • 2杨华,郑勤.肝癌放射治疗进展[J].东南大学学报(医学版),2012,31(4):488-491. 被引量:5
  • 3Hoffe SE, Finkelstein SE, Russell MS, et al. Nonsurgical options for hepatocellular carcinoma: evolving role of external beam radiotherapy [ J ]. Cancer Control, 2010, 17 ( 2 ) : 100-110.
  • 4Swaminath A, Dawson LA. Emerging role of radiotherapy in the management of liver metastases [ J ]. Cancer J, 2010, 16 ( 2 ) : 150- 155. DOI : 10.1097/PPO.0b013e3181 d7e8b3. Suramo.
  • 5I, Paivansalo M, Myllyla V. Cranio-caudal movements of the liver, pancreas and kidneys in respiration [ J]. Acta Radiol Diagn ( Stockh ), 1984, 25 ( 2 ) : 129-131.
  • 6Zhao JD, Xu ZY, Zhu J, et at. Application of active breathing control in 3-dimensional comformal radiation therapy for hepatocellular carcinoma : the feasibility and benefit [ J ]. Radiother Oncol, 2008, 87 : 439-444. DOI: 10.1016/j.radonc.2007.12.006.
  • 7Fuss M, Salter B J, Cavanaugh SX, et al. Daily uhrasound-based image-guided targeting for radiotherapy of upper abdominal malignancies [ J]. Int J Radiat Oncol Biol Phys, 2004, 59 (4) : 1245-1256. DOI : http ://dx.doi.org/10. I 016/j.ijrabp.2003.12.030.
  • 8Wong JW, Sharpe MB, Jaffray DA, et at. The use of active breathing control ( ABC ) to reduce margin for breathing motion [ J ]. Int J Radiat Oncol Biol Phys, 1999, 44 (4) : 911-919. DOI: http://dx. doi.org/10.1016/S0360-30 ! 6 ( 99 ) 00056-5.
  • 9Hawkins MA, Brock KK, Eccles C,et at. Assessment of residual error in liver position using kV cone-beam computed tomography for liver cancer high-precision radiation therapy [ J ]. Int J Radiat Oncol Biol Phys, 2006, ( 2 ) : 610-619.
  • 10焦升超,戴建荣,王维虎,门阔,李明辉,符贵山,毕楠,李晔雄.利用正交千伏级X线透视图像修正肝癌放疗摆位误差的可行性研究[J].中华放射肿瘤学杂志,2011,20(3):233-235. 被引量:3

二级参考文献43

  • 1梁世雄,蒋国梁,朱小东,傅小龙,陆海杰,潘朝阳,黄启芳,黎福祥,王安宇.原发性肝癌三维适形放疗后放射性肝病的影响因素[J].中华放射肿瘤学杂志,2005,14(4):284-288. 被引量:42
  • 2Feldkamp LA, Davis LC, Kreiss JW. Practical cone beam algorithm. J Opt Soc Am, 1984,1:612<i19.
  • 3Hristov DH, Fallone BG. A grey-level image alignment algorithm for registration of portal images and digitally reconstructed radiographs. Med Phys, 1996,23:75-84.
  • 4Sykes JR, Amer A, Czajka J, et al. A feasibility study for image guided radiotherapy using low dose, high speed, cone beam X-ray volumetric imaging. Radiother Oncol,2005,77:45-52.
  • 5Bland JM, Ahman DG. Comparing methods of measurement:why plotting difference against standard method is misleading. Lancet, 1995,346 : 1085-1087.
  • 6Astreinidou E, Bel AA, Raajmakers CP, et al. Adequat margins for random setup uncertainties in head and neck IMRT. Int J Radiat Oncol Biol Phys,2005,61:938-944.
  • 7Moseley D J, White E, Haycocks T, et al. Comparison of implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostate. Int J Radiat Oncol Biol Phys ,2004,60:229.
  • 8Jaffray DA, Siewerdsen JH, Wong JW, et al. Flat-panel conebeam conebeam computed tomography for image-guided radiation therapy. Int J Radiat Oncol Biol Phys,2002,53 : 1337- 1349.
  • 9Letonrneau D, Martinez AA, Lockman D, et al. Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients. Int J Radiat Oncol Biol Phys,2005,62: 1239- 1246.
  • 10Oldham M, Letourneau D, Watt L, et al. Cone-beam-CT guided radiation therapy: a model for on-line application. Radiother Oncol, 2005,75 : 271-278.