期刊文献+

分娩镇痛对孕产妇血清补体C_3、C_4及C反应蛋白的影响 被引量:3

Effect of labor analgesia on serum complement C_3,C_4 and C-reactive protein
原文传递
导出
摘要 目的评价分娩镇痛对产妇血清补体C3、C4及C反应蛋白(CRP)的影响。方法选择体质指数(BMI)18~24kg/m^2、妊娠38~41周单胎足月初产妇60例,采用随机数字表法分为镇痛组(30例)和对照组(30例)。镇痛组孕妇宫口开大≥3cm时硬膜外麻醉镇痛,对照组不采用任何镇痛措施。采用免疫速率散射比浊法测定孕妇进入产程时、宫口开大3cm、产后24h、产后48h血清补体C_3、C_4和CRP水平。结果 1镇痛组产后24h补体C_3、C_4分别为(1.02±0.01)g/L和(0.22±0.01)g/L,与进入产程时补体C_3、C_4[(1.41±0.01)g/L、(0.33±0.03)g/L]比较,差异有统计学意义(P<0.05)。镇痛组产后48h补体C_3、C_4分别为(1.33±0.02)g/L、(0.30±0.01)g/L,与产后24h比较,差异有统计学意义(P<0.05)。对照组产后24h补体C3、C4分别为(0.86±0.03)g/L和(0.19±0.01)g/L,与进入产程时[(1.47±0.05)g/L、(0.31±0.01)g/L]比较,差异有统计学意义(P<0.05)。两组产后48h补体C3、C4比较,差异有统计学意义(P<0.05)。2镇痛组产后24hCRP水平[(44.52±11.62)g/L],与进入产程时[(6.78±1.60)g/L]比较,差异有统计学意义(P<0.05);镇痛组产后48hCRP水平为(21.09±11.81)g/L,与对照组(33.22±11.82)g/L比较,差异有统计学意义(P<0.05)。结论硬膜外中麻醉镇痛能减轻应激反应造成的CRP增高,但补体系统无明显改变。 Objective To evaluate labor analgesia on maternal serum complement C_3、C_4 and C-reactive protein(CRP).Methods 60 patients with Body mass index(BMI) in 18-24,38 to 41 weeks of pregnancy,singletons full-term primipara recruited in the study.They were divided into two groups by random number table(n=30):epidural analgesia group and the control group.Start analgesia when pregnant cervix ≥3 cm(epidural analgesia group),the control group did not use any anesthesia.Serum complement C_3、C_4 and CRP content were measured by immune rate nephelometry assay at get into the labor(T1),cervix 3 cm(T2),postpartum 24 h(T3) and postpartum 48 h(T4).Results Levels of C_3、C_4 24 h postpartum in analgesia group[(1.02±0.01) g/L and(0.22±0.01) g/L ] were decreased compared to that before labor[(1.41±0.01) g/L,(0.33±0.03) g/L],the difference was statistically significant(P〈0.05).The levels of C_3 and C_4 in 48 h postpartum(1.33±0.02) g/L,(0.30±0.01) g/L and 24 h postpartum was significant different(P〈0.05).In control group,levels of C_3,C_4[(0.86±0.03) g/L,(0.19±0.01) g/L]24 h postpartum were significant lower than that of before labor[(1.47±0.05) g/L,(0.31±0.01) g/L](P〈0.05).Similarly results was found between 48 h postpartum group and control group(P〈0.05).CRP level(44.52±11.62) g/L in 24 h postpartum analgesia group,was significant higher than that before labor(6.78±1.60) g/L(P〈0.05).CRP level(21.09±11.81) g/L in 48 h postpartum analgesia group was lower than control group[(33.22±11.82) g/L](P〈0.05).Conclusion Epidural anesthesia analgesic can reduce the stress reaction caused by increased c-reactive protein and maintain the stability of the complement system.
出处 《中国妇产科临床杂志》 CSCD 北大核心 2016年第2期144-146,共3页 Chinese Journal of Clinical Obstetrics and Gynecology
关键词 分娩镇痛 补体C_3 补体C_4 C反应蛋白 labor analgesia complement 3 complement 4 c-reactive protein
  • 相关文献

参考文献10

二级参考文献63

共引文献138

同被引文献58

引证文献3

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部