期刊文献+

免疫磁珠磁振观测系统及其实验研究

The Observation System to The Magnetic Resonance of The Immune Magnetic Beads and The Experimental Research
下载PDF
导出
摘要 本文设计了一款观测免疫磁珠在振动磁场作用下磁振特性的系统,解决了处于微米级别的磁珠运动在肉眼下不可见的问题。实验研究表明,系统设计满足观测要求,且磁珠振动的频率和振幅受振动磁场的频率和振幅的影响。 The system was designed what can observe themagnetic resonance of the immune magnetic beads under the effectof vibrating magnetic field, and the problem was solved that themotion of magnetic beads at the micro level was not visible fromthe naked eye. The vibrating magnetic field was produced by thevibrating constant magnetic field actuated by piezoelectric ceramic.The microscope was used to observe the motion of magnetic beadsunder the action of vibrating magnetic field, and through theexperimental research, the following conclusions are obtained: theobservation system meets the demand and the vibration frequencyand amplitude of magnetic beads is influenced by the vibrationfrequency and amplitude of magnetic field.
作者 李平
机构地区 长治医学院
出处 《现代制造技术与装备》 2016年第3期27-28,共2页 Modern Manufacturing Technology and Equipment
基金 山西省高校科技研究开发项目(20091025)
关键词 免疫磁珠 磁振 观测 实验研究 immune magnetic beads, Magnetic resonance,Observation, Experimental study
  • 相关文献

参考文献5

二级参考文献37

  • 1OLSVIK O,POPOVIC T, SKJERVE E, et al. Magnetic separation techniques in diagnostic microbiology [ J ]. Clin microbial Rev, 1994,7( 1 ) :43-54.
  • 2JADEJA R,JANES M E,SIMONSON J G. lmmunomagnetic sepa- ration of Vibrio vulnificus with antiflagellar monoclonal antibody [ J ]. J Food Prot ,2010,73 ( 7 ) : 1288-1293.
  • 3VANHEE L M, MEERSSEMAN W, LAGROU K et al. Rapid and direct quantification of viable Candida species in whole blood by use of immunomagnetic separation and solid-phase cytometry [ J ]. J Clin M icrobiol,2010,48 ( 4 ) : 1126-1131.
  • 4TATAVARTHY A, PEAK K, VEGUILLA W, et al. An accelerated method for isolation of Salmonella enterica serotype Typhimurium from artificially contaminated foods, using a short preenrichment, immunomagnetic separation, and xylose-lysine-desoxycholate agar (6IX method)[J]. J Food Prot,2009,72(3) :583-590.
  • 5YANEZ M A, CARRASCO-SERRANO C, BARBERA V M, et al. Quantitative detection of Legionella pneumophila in water samples by immunomagnetic purification and real-time PCR amplification of the dotA gene [ J ]. Appl Environ Microbiol,2005,71 (7) :3433-3441.
  • 6YANG Z Y, SHIM W B, KIM K Y, et al. Rapid detection of enterotoxigenic Clostridium perfringens in meat samples using immunomagnetic separation polymerase chain reaction (IMBS- PCR)[J]. Agric Food Chem,2010,58(12) :7135-7140.
  • 7PARK Y, CHO Y H, JEE Y, et al. Immunomagnetic separation combined with real-time reverse transcriptase PCR assays for detection of norovirus in contaminated food [ J ]. Appl Environ Microbiol,2008, 74( 13 ) :4226-4230.
  • 8LEON-VELARDE C G, ZOSHERAFATEIN L, ODUMERU J A. Application of an automated immunomagnetic separation-enzyme immunoassay for the detection of Salmonella enterica subspecies enteriea from poultry environmental swabs [ J ]. J Microbiol Methods,2009 ,79( 1 ) : 13-17.
  • 9METZGER B C, KHASCHABI D, SCHONBAUER M, et al . Automated high-throughput immunomagnetic separation-PCR for detection of Mycobacterium avium Subsp. paratuberculosis in bovine milk[ J] . Int J Food Microbiol,2006, 110(3) :201-208.
  • 10ISLAMA M A, HEUVELINKA A E, TALUKDERV K A,et al. Immunoconcentration of Shiga toxin-producing Escherichia coli O157 from animal faeces and raw meats by using Dynabeads anti- E. coli O157 and the VIDAS system[ J] . Int J Food Microbiol, 2006,109(1-2) : 151-156.

共引文献38

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部