摘要
文章简述了SDZ-5070补偿中子测井仪工作原理,分析了造成该测井仪器故障的主要因素,提出了解决影响该测井仪器故障的方法和对策。根据故障现象认真总结出一套行之有效的维修方法,对SDZ-5070补偿中子测井仪的使用、维修有一定的参考指导意义。
The article briefly described the working principle of the SDZ 5070 Compensated Neutron Logging Tool and analyzed the main factors that caused the logging instrument malfunction.And then the corresponding methods and countermeasures of the solving logging instrument malfunction are put forward.We set up a set of effective maintenance methods according to the seriously fault phenomenon.In addition,the methods are very significant for the use and the maintenance of the SDZ-5070 Compensated Neutron Logging Tool.
出处
《内蒙古石油化工》
CAS
2015年第19期73-75,共3页
Inner Mongolia Petrochemical Industry
关键词
补偿中子测井仪
热中子
探测器
长短计数率
故障分析
Compensated neutron logging
Thermal neutron detector count rate
Length
Failure analysis