An investigation on the dosimetric impact of hip prosthesis in radiotherapy

An investigation on the dosimetric impact of hip prosthesis in radiotherapy
下载PDF
导出
摘要 The objectives of this study are to evaluate the dosimetric impact of hip prosthesis using ELEKTA linac X-rays and compare the dose perturbations of metallic and nonmetallic hip prostheses. The local dose distributions of typical hip prostheses were calculated for 4, 8, and 15 MV beams by Geant4. Three prosthesis materials were selected in calculation to reveal the relation between material type and local dose perturbations of prostheses. Furthermore,the effect of nominal energy on prosthesis perturbation was also discussed and analyzed. Taking the calculated dose to the hip joint as reference, considerable differences were observed between prostheses and hip joints. In the prosthesis shadow region, the relative dose decreasing was up to 36, 21, and 16 % for the Co–Cr–Mo alloy, titanium alloy, and ceramic prostheses, respectively. In backscattering region, the relative dose increasing was about1–7 %. Overall, the results show that the dose perturbation effect of prostheses was mainly determined by material type, nominal energy, and density. Among these typical hip prostheses, ceramic prosthesis introduces the lowest dose perturbations. The objectives of this study are to evaluate the dosimetric impact of hip prosthesis using ELEKTA linac X-rays and compare the dose perturbations of metallic and nonmetallic hip prostheses. The local dose distributions of typical hip prostheses were calculated for 4, 8, and 15 MV beams by Geant4. Three prosthesis materials were selected in calculation to reveal the relation between material type and local dose perturbations of prostheses. Furthermore, the effect of nominal energy on prosthesis perturbation was also discussed and analyzed. Taking the calculated dose to the hip joint as reference, considerable differences were observed between prostheses and hip joints. In the pros- thesis shadow region, the relative dose decreasing was up to 36, 21, and 16 % for the Co-Cr-Mo alloy, titanium alloy, and ceramic prostheses, respectively. In backscat- tering region, the relative dose increasing was about 1-7 %. Overall, the results show that the dose perturbation effect of prostheses was mainly determined by material type, nominal energy, and density. Among these typical hip prostheses, ceramic prosthesis introduces the lowest dose perturbations.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2016年第1期29-36,共8页 核技术(英文)
基金 supported by Heilongjiang Province Natural Science Foundation (No. A200805) the Education Department of Heilongjiang Province (No. 12521425) the postdoctoral research start-up funds of Heilongjiang Province (No. LBHQ11013)
关键词 髋关节 剂量学 假体 放射治疗 扰动效应 GEANT4 X射线剂量 直线加速器 Medical linac Hip prosthesis Ceramic Dose perturbation Monte Carlo method
  • 相关文献

参考文献2

二级参考文献28

  • 1Bird A J, Ramsden D. Nucl Instrum Methods Phys A, 1990, 299: 480-483.
  • 2Majewski S, Farzanpay E Goode A, et al. Nucl Instrum Methods Phys A, 1998, 409: 520-523.
  • 3Garibaldi F, Cisbani E, Cusanno E et al. Nucl Instrum Methods Phys A, 2001,471: 222-228.
  • 4Craig S L. Nucl Instrum Methods Phys A, 2003, 497: 60-74.
  • 5Pani R, Pellegrini R, Cinti M N, et al. Nucl Instrum Methods Phys A, 2004, 527: 54-57.
  • 6GEANT, Detector Description and Simulation Tool, Application Software Group. < http: //wwwasdoc. web. cem.ch / wwwasdoc / geantole / GEANTMAIN. html>.
  • 7Pani R, Scafe R, Pellegfini R, et al. Nucl Instrum Methods Phys A, 2002, 477: 72-76.
  • 8Position sensitive photomultiplier tube with crossed wire anodes R2486 series, Specifications manual (in Japanese). Hamamatsu: K.K. Electron Tube Center, 1993: 1-53. http: //www. Hamamatsu.com.
  • 9Guerra D, Belcari N. Nucl Instrum Methods Phys A, 2007, 583: 119-124.
  • 10Adler J R, Chang S D, Murphy M J, et al. Stereotact Funct Neurosurg, 1997, 69: 124-128.

共引文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部