摘要 利用DeST-h软件对10组0-90 mm不同外墙保温层厚度的典型西北新农村建筑采暖能耗进行了模拟分析,并确定了最佳外墙经济保温层厚度。结果表明外墙保温可明显降低建筑采暖能耗,采暖节能率可达到26%,外墙保温层厚度的增加在降低建筑采暖能耗的同时增大了外墙保温投资费用,采用生命周期成本分析法确定西北新农村建筑采用挤塑保温板为保温材料时最佳外墙经济保温层厚度为55 mm。 The energy consumption for heating is analyzed by DeST-h through the simulation of typical new rural construction in northwest China with 10 groups of 0 -90 mm different insulation layers.The results show that external wall insulation reduces the energy consumption required for space heating and the energy-saving rate could be 26%. The increase in insulation thickness reduces the energy consumption required for space heating, while the insulation cost increases. Economic analysis for optimum insulation thickness are carried out by the LCC method with XPS and the optimum external wall insulation thickness is 55 mm for typical new rural constructions in northwest China.
出处 《建筑节能》 CAS 2016年第3期33-36,共4页 BUILDING ENERGY EFFICIENCY
基金 国家863计划课题(2014AA052801) 甘肃省杰出青年基金(2012GS05601) 兰州理工大学"红柳杰出人才计划"(Q2011) 甘肃省建设科技攻关项目(JK2010-29)
关键词 保温层厚度 新农村建筑 DEST-H 建筑能耗 insulation thickness new rural construction DeST-h building energy consumption
  • 相关文献

参考文献15

  • 1Bao-Jie He,Li Yang,Miao Ye.Building energy efficiency in China rural areas:Situation,drawbacks,challenges,corresponding measures and policies[J].Sustainable Cities and Society,2014,(11):7-15.
  • 2Farhanieh B,Sattari S.Simulation of energy saving in Iranian buildings using integrative modelling forinsulation[J].Renewable energy,2006,31(4):417-425.
  • 3Ozel M.Effect of wall orientation on the optimum insulation thickness by using a dynamic method[J].Applied Energy,2011,88(7):2429-2435.
  • 4刘静,张旭,张小波.夏热冬冷地区围护结构保温对夏季住宅建筑的影响研究[J].制冷与空调(四川),2015,29(3):315-319. 被引量:4
  • 5王厚华,庄燕燕,吴伟伟.夏热冬冷地区围护结构热工性能节能分析[J].同济大学学报(自然科学版),2010,38(11):1641-1646. 被引量:25
  • 6Shanmuga Sundaram A,Bhaskaran A.Optimum insulation thickness of walls for energy-saving in hotregions of India[J].International Journal of Sustainable Energy,2014,33(1):213-226.
  • 7Kaynakli O.A review of the economical and optimum thermal insulation thickness for building applications[J].Renewable and Sustainable Energy Reviews,2012,16(1):415-425.
  • 8清华大学DeST开发组.建筑环境系统模拟分析方法-DesT[M].北京:中国建筑工业出版社,2005.
  • 9朱轶韵,刘加平.西北农村建筑冬季室内热环境研究[J].土木工程学报,2010,43(S2):400-403. 被引量:39
  • 10中国建筑标准设计研究院,清华大学.GBT 50824-2013,农村居住建筑节能设计标准[S].北京:中国建筑工业出版社,2013.