二次再热是火电机组提高效率的有效手段,国内首台二次再热机组的成功投运,为今后火电项目的建设,提供了新的选项。文章介绍了东方二次再热汽轮机启动系统的配置、启动参数的选择以及机组的启动和调试中需注意的事项和存在的问题,为今后同类机组的投运和设计提供了参考。
Double-reheat is an effective mean to increase efficiency of steam turbine.New choice has been provided for the future construction of thermal power projects as the domestic first double-reheat steam turbine which operates successfully. This article introduces the configuration of start-up system, the choice of start-up parameter and existing problems during start-up and commissioning, it provides a reference for the design and operation of the same type steam turbine.
出处
《东方汽轮机》
2016年第1期73-76,共4页
Dongfang Turbine
关键词
首台
二次再热
旁路
启动
the first set
double-reheat
by-pass system
start-up