摘要
变压器的温升关系着变压器能否可靠运行。该文主要介绍干式变压器温升试验的一种试验方法——模拟负载法,通过对此试验方法的介绍,深入了解温升试验的过程,并通过详细的实例计算,得出此方法准确,可靠,与设计值相差甚小。并以此验证该实例变压器温升合格。
Transformer Temperature Rise has relation to the reliable operation oftransformer.This paper mainly introduces a kind oftestmethod--Simulant Loading Method for Dry-type Transformer Temperature Rise Test.By this experimentmethod is introduced,and a deep understanding ofthe process oftemperature rise experiment,through the detailed calculation,itis concluded thatthis method is accurateand,reliable,and the difference isverysmallfordesignvalue.And toverifythistransformertemperatureriseisqualified.
出处
《电子质量》
2016年第3期64-65,79,共3页
Electronics Quality
基金
山东省自然科学基金(编号:ZR2011FM008)
青岛市创新型中小企业培养计划项目(编号:11-1-4-2-gx)
关键词
干式变压器
温升实验
空载绕组温升
负载绕组温升
Dry-type transformer
Temperature rise test
No-load winding temperature rise
Load winding temperature rise