摘要
针对引信体外射频电源的供电控制问题,提出了基于发射后坐过载传感器的引信体外射频电源供电控制方法。该方法采用后坐过载传感器,通过弹簧约束切刀并在后坐过载作用下切断导体的方式识别发射环境,并控制供电电路通断,实现引信体外射频电源在出炮口附近对发火控制与起爆电路供电;在引信装定时检测传感器导体的通断,提高引信体外射频电源供电安全性。原理样机验证试验结果表明,该方法能够控制引信体外射频电源仅在出炮口附近对发火控制与起爆电路供电,发射过载传感器与上电控制电路简单、易于小型化。
To control the power supply of the externally RF power for fuze,the supply control method of the externally RF power for fuze based on the launch recoil overload sensor was proposed.The launch recoil overload sensor could distinguish the difference environment between ammunition service and ammunition launch,and generated the control signal to switch on the circuit of power supply of the externally RF power,when the cutter cut off the wire by the pull of recoil,which was hold upper by spring.To avoid false detonation,the state of wire was checked during fuze setting,and the control and detonate circuit of fuze became short-circuit if the wire was broken before launch.The prototype test results showed that the externally RF power was discharged and the control and detonate circuit of fuze begins to start-up just during muzzle with the supply control method.The sensor and control circuit had advantages of simple and easily miniaturization.
出处
《探测与控制学报》
CSCD
北大核心
2016年第1期24-27,共4页
Journal of Detection & Control