期刊文献+

空气过滤器对比分析研究 被引量:2

Comparative and Analytic Research on Air Filter
下载PDF
导出
摘要 众所周知,空气污染日益加剧,室内空气超标。论文基于过滤器过滤原理不同,对3种不同类型的过滤器进行对比分析研究,揭示出各种过滤器的优缺点;并以国家博物馆过滤效率数据为研究背景,在相同工况下分析得出各种过滤器的过滤工况的使用条件,为今后进行过滤器选择奠定基础。 It is well known that air pollution is increasingly intensifying. Indoor air quality is over standard. Based on different filter principle of filter, three different types of filters carry on comparative analysis. The paper reveals the advantages and disadvantages of various filters. And the research background is in national museum of China. In the same working conditions, the paper analyses on application conditions of various filters, and to provide basis for future selection of filter.
作者 曹思循
机构地区 中国国家博物馆
出处 《智能建筑与城市信息》 2016年第3期56-58,共3页 Intelligent Building and City Infomation
关键词 PM2.5 空气污染 空气过滤器 过滤效率 PM2.5 air pollution air filter filtration efficiency
  • 相关文献

参考文献1

二级参考文献25

  • 1JANSSEN N A, HOEK G, SIMIC-LAWSON M, etal. Black carbon as an additional indicator of the adverse health effects of airborne particles compared with PM10 and PM2. 5 [J]. Environmental Health Perspectives, 2011, 119(12) : 1691-1699.
  • 2WEICHENTHAL S, VILLENEUVE P J, BURNETT R T, et al. Long-term exposure to fine particulate matter: association with nonaccidental and cardiovascular mortality in the agricultural health study cohort [ J]. Environmental Health Perspectives, 2014, 122(6): 609-615.
  • 3CAKMAK S, DALES R, KAURI L M, et al. Metal composition of fine particulate air pollution and acute changes in cardiorespiratory physiology [ J ] Environmental Pollution, 2014, 189(12): 208-214.
  • 4KIM K H, KABIR E, KABIR S. A review on the human health impact of airborne particulate matter [J]. Environment International, 2015, 74:136-143.
  • 5DIAPOULI E, ELEFTHERIADIS K, KARANASIOU A A, et al. Indoor and outdoor particle number and mass concentrations in Athens. Sources, sinks and variability of aerosol parameters [J]. Aerosol & Air Quality Research, 2011, 11(6): 632-642.
  • 6MASSEY D, MASIH J, KULSHRESTHA A, et al. Indoor/outdoor relationship of fine particles less than 2. 5 μm (PM2. 5) in residential homes locations in central Indian region[J]. Building and Environment, 2009, 44(10) ,2037-2045.
  • 7CYRYS J, PITZ M, BISCHOF W, et al. Relationship between indoor and outdoor levels of fine particle mass, particle number concentrations and black smoke under different ventilation conditions [-J]. Journal of Exposure Analysis and Environmental Epidemiology, 2004, 14(4).. 275-283.
  • 8OZKAYNAK H, XUE J, SPENGLER J, et al. Personal exposure to airborne particles and metals: results from the particle TEAM study in Riverside, California[J]. Journal of Exposure Analysis Environmental Epidemiology, 1996, 6 (1) : 57- 78.
  • 9LI G Z, WANG Q Q, WANG J L. Chinese standard requirements on indoor environmental quality for assessment of energy-efficient buildings [-J]. Indoorand Built Environment, 2014, 23(2): 194-200.
  • 10LIUID L, NAZAROFF W W. Particle penetration through building cracks [-J]. Aerosol Science and Technology, 2003, 37(7): 565-573.

共引文献24