摘要 由于均匀的大体积放射性废物桶制备困难,放射性废物桶分段γ扫描(SGS)装置的活度探测效率多采用间接的方式进行刻度。壳源法制备的废物桶以线状源为核心,制备简单,结构灵活,是最佳的间接方法之一。本文通过对均匀填充型放射性水溶液桶和壳源法制备的放射性废物桶测量比较,证明壳源法制备的放射性废物桶在进行SGS装置探测效率刻度时与均匀桶是等效的,可作为此类装置探测效率的校准源。 Due to the difficulty in preparation of homogeneous radioactive waste drum with large volume,the detection efficiency of segmentedγscanning(SGS)device is scaled usually with indirect approaches.Shell source method is one of best ways,which uses linear source as the principal part.It is not so complicated for the preparation,and the structure is flexible.Based on the comparison of measurement results from uniform drums and drums prepared with shell source method,it is proved that they are equivalent in the calibration of efficiency.The latter can be taken as the reference source of SGS device.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2016年第3期558-564,共7页 Atomic Energy Science and Technology
关键词 壳源法 分段γ扫描装置 校准 等效性 shell source method segmentedγscanning device calibration equivalent
  • 相关文献

参考文献13

二级参考文献22

  • 1乔盛忠,朱荣保,郏惠忠,刘亨军,杨留成,唐培家,丁大纯,陈国安,李纪民,朴勇男,贾向军.模拟废包壳中残留铀含量的有源中子测定[J].原子能科学技术,1994,28(1):8-15. 被引量:4
  • 2朱荣保,谭亚军,袁晓鑫,吕钊,曹斌,吴昕,程炳皓,许晓东,江金才.大型高分辨分段γ扫描装置的研制[J].原子能科学技术,1994,28(1):16-25. 被引量:13
  • 3PARKER J L. The use of calibration standards and the correction for sample self attenuation in gamma-ray nondestructive assay, LA-10045 [R]. USA: Los Alamos National Laboratory, 1986.
  • 4何丽霞.探测器表征技术在核保障非破坏性伽玛检测系统中的应用研究[D].北京:中国原子能科学研究院,2009.
  • 5PARKER J L. The use of calibration standards and the correction for sample self attenuation in gamma-ray nondestructive assay, LA-10045[R]. USA~ Los Alamos National Laboratory, 1986.
  • 6EXPARTERO A G, PINA G, SUAREZ J A. Development and application of a radioactivity characterization system for low-level radioactive waste[J]. Nuclear Instruments and Methods inPhysics Research A, 1999, 422(1-3): 790-794.
  • 7王奕博.分段Y扫描系统无源刻度技术研究[D].北京:中国原子能科学研究院,2009.
  • 8PARKER J L.The use of calibration standards and the correction for sample self attenuation in gamma-ray nondestructive assay:LA-10045 Rev[R].US:Los Alamos National Laboratory,1986.
  • 9DONG R,NORBERT E.Passive nondestructive assay of nuclear materials:NUREG/CR-5550 LA-UR-90-732[R].US:Nuclear Regulatory Commission,1990.
  • 10HSUE S T,STEWART J E.Guide to nondestructive assay standard preparation,criteria,availability,and practical considerations:La-13340-Ms[R].US:Los Alamos National Laboratory,2000.

共引文献40

同被引文献73

引证文献5

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部