不同浓度对比剂联合能谱CT扫描在肾动脉CT血管成像中的应用 被引量:5

Different Concentrations of Contrast Media Combined with Spectral CT Imaging in Renal CT Angiography
下载PDF
导出
摘要 目的采用不同浓度对比剂联合能谱CT进行肾动脉CT血管成像(CTA)检查,探讨减少患者碘摄入量并保证影像质量的可行性。资料与方法 100例患者随机分为5组行肾动脉能谱CT肾动脉造影检查,对比剂总量为1 ml/kg,5组患者注射对比剂浓度为370 mg I/ml、333 mg I/ml、296 mg I/ml、259 mg I/ml、222 mg I/ml,用层厚0.625 mm的最佳对比噪声比(CNR)ke V图像对肾动脉行容积再现和最大密度投影。计算图像信噪比(SNR)及CNR,比较5组图像质量主观评分,并评价2名医师对图像质量主观评价的一致性。结果肾动脉最佳CNR单能量范围为48~53 ke V。370 mg I/ml、333 mg I/ml、296 mg I/ml、259 mg I/ml组图像SNR、CNR及2名医师评分差异无统计学意义(P〉0.05);上述对比剂浓度组与222 mg I/ml组图像SNR、CNR及2名医师评分差异有统计学意义(P〈0.05)。2名医师评价上述对比剂浓度组图像质量的一致性(Kappa=0.83,P〈0.05)高于222 mg I/ml组(Kappa=0.63,P〈0.05)。结论能谱CT在肾动脉CTA检查中能显著降低对比剂浓度。 Purpose To explore the feasibility of reducing patients iodine intake and ensuring image quality as well by using different concentration of contrast media combined with spectral CT imaging in renal CT angiography(CTA). Materials and Methods One hundred patients who underwent renal spectral CT examination were randomly divided into 5 groups. The contrast media dose were offered at 1 ml/kg, and contrast media concentration for the 5 groups were 370 mg I/ml, 333 mg I/ml, 296 mg I/ml, 259 mg I/ml and 222 mg I/ml, respectively. The ke V maps of the optimal contrast noise ratio(CNR) with a thickness of 0.625 mm were used to obtain volume rendering(VR) and maximum intensity projection(MIP) to show the renal artery. The signal noise ratio(SNR) and contrast noise ratio(CNR) of the images were calculated. The overall imaging quality of 5 groups was evaluated by 2 radiologists. Consistence between 2 readers was evaluated. Results The monochromatic image at 48-53 ke V was found to demonstrate the best CNR for the renal artery. There was no statistic difference for SNR, CNR and the consistence among the groups of contrast media concentration of 370 mg I/ml, 333 mg I/ml, 296 mg I/ml and 259 mg I/ml(P〈0.05). While SNR, CNR and the consistence at the contrast media concentration of 222 mg I/ml were significantly different with other contrast media concentration groups(P〈0.05). When compared with 222 mg I/ml group, the consistence between the two readers was higher for the contrast media concentration of 370 mg I/ml, 333 mg I/ml, 296 mg I/ml, 259 mg I/ml groups(P〈0.05). Conclusion The spectral CT can significantly reduce the contrast media concentration in renal artery CTA.
出处 《中国医学影像学杂志》 CSCD 北大核心 2016年第2期153-156,共4页 Chinese Journal of Medical Imaging
基金 河北省政府资助临床医学优秀人才培养和基础课题研究项目计划 河北大学国家级大学生创新创业训练计划项目(201510075026) 河北大学研究生教育教学改革研究项目(YJ11-33) 河北大学附属医院青年基金(2015Q 002 2015 Q 017)
关键词 肾疾病 肾动脉 体层摄影术 X线计算机 血管造影术 造影剂 浓度 质量控制 Kidney diseases Renal artery Tomography X-ray computed Angiography Contrast media Concentration Iodine Quality control
  • 相关文献

参考文献15

  • 1Stacul F,van der Molen AJ,Reimer P,et al.Contrast induced nephropathy:updated ESUR Contrast Media Safety Committee guidelines.Eur Radiol,2011,21(12):2527-2541.
  • 2Thomsen HS.Recent hot topics in contrast media.Eur Radiol,2011,21(3):492-495.
  • 3Lv PJ,Lin XZ,Li JY,et al.Differentiation of small hepatic hemangioma from small hepatocellular carcinoma:recently introduced spectral CT method.Radiology,2011,259(3):720-729.
  • 4Paul J,Bauer RW,Maentele W,et al.Image fusion in dual energy computed tomography for detection of various anatomic structures-effect on contrast enhancement,contrast-to-noise ratio,signal-to-noise ratio and image quality.Eur J Radiol,2011,80(2):612-619.
  • 5Singh S,Kalra MK,Shenoy-Bhangle AS,et al.Radiation dose reduction with hybrid iterative reconstruction for pediatric CT.Radiology,2012,263(2):537-546.
  • 6Thomsen HS.Contrast media safety-an update.Eur J Radiol,2011,80(1):77-82.
  • 7Qi LP,Li Y,Tang L,et al.Evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction with the same group of patients.Br J Radiol,2012,85(118):e906-e911.
  • 8夏巍,宋旭升,尹肖睿,李瑞雪,吴晶涛.宝石CT能谱最佳单能量图像在下肢动脉造影中的应用[J].中国医学影像学杂志,2014,22(11):842-845. 被引量:13
  • 9张军,邓克学,刘志远,张敏.CT能谱成像鉴别诊断胰腺癌与肿块型胰腺炎[J].中国医学影像学杂志,2015,23(4):268-272. 被引量:27
  • 10Zhao LQ,He W,Li JY,et al.Improving image quality in portal venography with spectral CT imaging.Eur J Radiol,2012,81(8):1677-1681.

二级参考文献61

  • 1王玉珍,许樟荣.第五届国际血管外科暨第一届国际糖尿病血管疾病会议(糖尿病足部分)纪要[J].中华糖尿病杂志(1006-6187),2005,13(2):152-153. 被引量:184
  • 2宋彬,闵鹏秋,吴苾,印隆林,刘杰,李迎春,徐隽.磁共振VIBE序列鉴别胰腺癌与肿块型慢性胰腺炎的价值探讨[J].放射学实践,2006,21(5):498-502. 被引量:13
  • 3Mirko D'Onofrio,Giulia Zamboni,Alessia Tognolini,Roberto Malagò,Niccolò Faccioli,Luca Frulloni,Roberto Pozzi Mucelli.Mass-forming pancreatitis: Value of contrast-enhanced ultrasonography[J].World Journal of Gastroenterology,2006,12(26):4181-4184. 被引量:29
  • 4姜滨,张龙江,沈文,祁吉.多层螺旋CT血管成像在肝静脉解剖中的应用研究[J].临床放射学杂志,2007,26(7):683-687. 被引量:6
  • 5Sun Z.Diagnostic accuracy of multislice CT angiography in peripheral arterial disease.J Vasc Interv Radiol,2006,17(12):1915-1921.
  • 6Matsumoto K,Jinzaki M,Tanami Y,et al.Virtual monochromatic spectral imaging with fast kilovoltage switching:improved image quality as compared with that obtained with conventional 120-k Vp CT.Radiology,2011,259(1):257-262.
  • 7Pache G,Krauss B,Strohm P,et al.Dual-energy CT virtual noncalcium technique:detecting posttraumatic bone marrow lesions-feasibility study.Radiology,2010,256(2):617-624.
  • 8Takahashi N,Vrtiska TJ,Kawashima A,et al.Detectability of urinary stones on virtual nonenhanced images generated at pyelographic-phase dual-energy CT.Radiology,2010,256(1):184-190.
  • 9Lin XZ,Miao F,Li JY,et al.High-definition CT gemstone spectral imaging of the brain:initial results of selecting optimal monochromatic image for Beam-Hardening artifacts and image noise reduction.J Comput Assist Tomogr,2011,35(2):294-297.
  • 10Lv P,Lin XZ,Li J,et al.Differentiation of small hepatic hemangioma from small hepatocellular carcinoma:recently introduced spectral CT method.Radiology,2011,259(3):720-729.

共引文献84

同被引文献29

引证文献5

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部