期刊文献+

Fluorescent carbon dots derived from lactose for assaying folic acid 被引量:2

Fluorescent carbon dots derived from lactose for assaying folic acid
原文传递
导出
摘要 The fluorescent carbon dots were successfully synthesized by simply heating the mixture of lactose and Na OH solution. The as-synthesized carbon dots had been systematically characterized by fluorescence, Fourier transform infrared(FTIR), high resolution transmission electron microscopy(HR-TEM) and ^(13)C NMR. Since the fluorescence of the carbon dots was efficiently quenched by folic acid, the carbon dots were employed as selective fluorescence probes for detecting folic acid, depending on the formation of hydrogen bond among the functional group of folic acid(–OH, –COOH and –NH_2) and –OH and –COOH of the carbon dots. Moreover, the decrease of fluorescence intensity was capable of detecting folic acid in a linear range of 6×10^(-5)–8×10^(-8) mol/L with a detection limit of 1.2×10^(-9)mol/L at a signal-to-noise ratio of 3, suggesting a promising assay for folic acid. Significantly, the practicability of this fluorescence probe to assay folic acid in human urine samples was further evaluated. The fluorescent carbon dots were successfully synthesized by simply heating the mixture of lactose and NaOH solution. The as-synthesized carbon dots had been systematically characterized by fluorescence, Fourier transform infrared (FTIR), high res- olution transmission electron microscopy (HR-TEM) and 13C NMR. Since the fluorescence of the carbon dots was efficiently quenched by folic acid, the carbon dots were employed as selective fluorescence probes for detecting folic acid, depending on the formation of hydrogen bond among the functional group of folic acid (-OH, -COOH and -NH2) and -OH and -COOH of the carbon dots. Moreover, the decrease of fluorescence intensity was capable of detecting folic acid in a linear range of 6×10-5-8×10-8 mol/L with a detection limit of 1.2×10-9 mol/L at a signal-to-noise ratio of 3, suggesting a promising assay for folic acid. Significantly, the practicability of this fluorescence probe to assay folic acid in human urine samples was further evaluated.
出处 《Science China Chemistry》 SCIE EI CAS CSCD 2016年第4期487-492,共6页 中国科学(化学英文版)
基金 supported by the Science Foundation of Southwest University (SWU114053) the Natural Science Foundation Project of CQ CSTC (cstc2013jcyj A10117) the Fundamental Research Funds for the Central Universities (XDJK2015A005, XDJK2016D033) the Innovative Research Project for Postgraduate Students of Chongqing (CYS14049)
关键词 CARBON quantum dots fluorescence quenching 荧光探针 叶酸 测定 乳糖 NaOH溶液 高分辨率 傅里叶变换
  • 相关文献

参考文献24

  • 1Prato M. JMater Chem, 1997, 7:1097-1109.
  • 2Yang ST, Cao L, Luo PG, Lu F, Wang X, Wang H, Meziani MJ, Liu Y, Qi G, Sun YP. JAm Chem Soc, 2009, 131:11308.
  • 3He DH, Zheng CB, Wang Q, He CL, Lee YI, Wu L, Hou XD. Talanta, 2015, 142:51-56.
  • 4Bourlinos AB, Stassinopoulos A, Anglos D, Zboril R, Karakassides M, Giannelis EP. Small, 2008, 4:455-458.
  • 5Ploehn HJ, Gu YL, Xu XY, Raker K, Gearheart L, Ray R, Scrivens WA. JAm Chem Soc, 2004, 126:12736-12737.
  • 6Cao L, Sahu S, Anilkumar P, Bunker CE, Xu J, Shiral Fernando KA, Wang P, Guliants EA, Tackett II KN, Sun YP. JAm Chem Soc, 2011, 133:4754-4757.
  • 7Li HT, He XD, Kang ZH, Huang H, Liu Y, Liu JI, Lian SY, Tsang CHA, Yang XB, Lee ST. Angew Chem lnt Ed, 2010, 49:4430-4434.
  • 8Cao L, Wang X, Meziani MJ, Lu F, Wang H, Luo PJG, Lin Y, Har- ruff BA,Veca LM, Murray D, Xie SY, Sun YP. J Am Chem Soc, 2007, 129:11318-11319.
  • 9Guo YM, Wang Z, Shao HW, Jiang XY. Carbon, 2013, 52:583-589.
  • 10Pan D, Zhang J, Li Z, Wu C, Yan X, Wu M. Chem Commun, 2010 46:3681-3683.

同被引文献21

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部