期刊文献+

1100t/h塔式锅炉加装高温换热器分析 被引量:2

Study on installation of high-temperature heat exchanger for a 1100t/h tower type boiler
下载PDF
导出
摘要 某机组1 100t/h塔式锅炉省煤器出口烟气温度过高,不能满足选择性催化还原(SCR)脱硝设备的正常运行,对此,通过在省煤器出口加装高温换热器,有效降低了SCR反应器入口烟气温度,保证了SCR催化剂的安全稳定运行;同时,利用高温换热器加热凝结水,排挤低压抽汽,使机组供电煤耗降低约2.34g/(kW·h),节能效果显著。 The flue gas temperature at economizer outlet was too high in a 1 100t/h power plant tower type boiler,which can not ensure the normal operation of the selective reduction catalytic(SCR)denitration devices.Thus,a high temperature heat exchanger was installed at the economizer outlet,and the flue gas temperature at the SCR device inlet was effectively reduced,which ensured the safe and steady operation of the SCR catalyst.Moreover,the high temperature heat exchanger can be applied to heat the condensate to crowd the low-pressure steam extraction,therefore,the net coal consumption of the unit decreased by about2.34g/(kW·h),indicating the energy saving benefits were great.
出处 《热力发电》 CAS 北大核心 2016年第3期121-124,共4页 Thermal Power Generation
关键词 塔式锅炉 高温换热器 省煤器 烟气温度 选择性催化还原 脱硝 节能 tower type boiler high-temperature heat exchanger economizer flue-gas temperature SCR denitration energy saving
  • 相关文献