期刊文献+

Non-uniformity effects of the inter-foil distance on GEM detector performance

Non-uniformity effects of the inter-foil distance on GEM detector performance
原文传递
导出
摘要 The non-uniformity effect of the inter-foil distance has been studied using a gaseous electron multiplication(GEM) detector with sensitive area of 50mm×50mm. A gradient of the inter-foil distance is introduced by using spacers with different heights at the two ends of the foil gap. While the cluster size and the intrinsic spatial resolution show insignificant dependence on the inter-foil distance, the gain exhibits an approximately linear dependence on the inter-foil distance. From the slope, a quantitative relationship between the change of the inter-foil distance and the change of the gain is derived, which can be used as a method to evaluate the non-uniformity of the foil gap in the application of large-area GEM detectors. The non-uniformity effect of the inter-foil distance has been studied using a gaseous electron multiplication(GEM) detector with sensitive area of 50mm×50mm. A gradient of the inter-foil distance is introduced by using spacers with different heights at the two ends of the foil gap. While the cluster size and the intrinsic spatial resolution show insignificant dependence on the inter-foil distance, the gain exhibits an approximately linear dependence on the inter-foil distance. From the slope, a quantitative relationship between the change of the inter-foil distance and the change of the gain is derived, which can be used as a method to evaluate the non-uniformity of the foil gap in the application of large-area GEM detectors.
出处 《Chinese Physics C》 SCIE CAS CSCD 2016年第4期56-61,共6页 中国物理C(英文版)
基金 Supported by National Natural Science Foundation of China(11375094,U1332207,11120101004) by Tsinghua University Initiative Scientific Research Program
关键词 uniformity multiplication intrinsic gaseous strips correspondence readout normalized fitting directions uniformity multiplication intrinsic gaseous strips correspondence readout normalized fitting directions
  • 相关文献

参考文献22

  • 1F. Sauli, Nucl. Instrum. Methods A, 386:531 (1997).
  • 2T. Barvich et al, Nucl. Instrum. Methods A, 485:477 (2002).
  • 3F. Simon et al, IEEE Trans. Nucl. Sci., 54:2646 (2007).
  • 4Y. L. Li et al, Nucl. Instrum. Methods A, 596:305 (2008).
  • 5V. M. Aulchenko et al, Nucl. Instrum. Methods A, 598:112 (2009).
  • 6F. Simon F et al, Nucl. Instrum. Methods A, 598:432 (2009).
  • 7P. Martinengo et al, Nucl. Instrum. Methods A, 604:8 (2009).
  • 8K. Fujita et M, Nucl. Instrum. Methods A, 608:48 (2009).
  • 9F. Murtas et al, Nucl. Instrum. Methods A, 61T: 237 (2010).
  • 10C. Altunbas et al, Nucl. Instrum. Methods A, 490:177 (2002).