期刊文献+

散光矫治型人工晶体植入治疗后房型有晶体眼近视散光临床分析 被引量:5

Effect of toric implantable collamer len implantation on myopic astigmatism in posterior chamber type phakic eye
原文传递
导出
摘要 目的评估散光矫治型人工晶体(toric implantable collamer len,TICL)植入治疗后房型有晶体眼近视散光术后轴向稳定性和视功能。方法 62例(80眼)屈光不正患者进行TICL植入手术,术后测量散光矫治情况;术后7d和术后6个月采用裂隙灯分别测量TICL散光轴位;术后随访6个月调查患者视功能满意度,填写视功能评价表。结果术后6个月,患者术眼裸眼视力达0.5以上;术后7d和术后6个月,散光分别降至(-0.45±0.27)D、(-0.41±0.21)D,散光变化值为(0.040±0.012)D;术后7d至术后6个月,轴位偏离度为(2.46±1.28)°;术后患者对视觉功能改善满意度在90%以上。结论 TICL治疗中、高度近视散光安全、有效。 Objective To assess the stability of axis and visual function after toric implantable collamer len(TICL)implantation for myopic astigmatism in posterior chamber type phakic eye.Methods Total 80 eyes in 62 patients underwent TICL implantation for correcting myopic astigmatism. The postoperation astigmatism correction was measured.The deviation of axis of TICL was detected by slit lamp 7 days and 6 months after operation.The patients were asked to fill in the visual function evaluation scale to evaluate their visual function satisfaction degree.Results Six months after operation,the naked vision was over 0.5.The mean refractive cylinder decreased to(-0.45±0.27)D and(-0.41±0.21)D respectively 7 days and 6months after operation.The mean change value of astigmatism was(0.04±0.012)D.The mean axis deviation of TICL was(2.46±1.28)°from 7 days to 6 months after operation.More than 90% patients were satisfied with their visual function.Conclusions TICL implantation is safe and effective for moderate and high myopic astigmatism.
作者 董良 陈彬川
出处 《中华实用诊断与治疗杂志》 2016年第4期393-395,共3页 Journal of Chinese Practical Diagnosis and Therapy
基金 郑州市科技局基金(121PCXTD523)
关键词 高度近视散光 后房型 散光矫治型人工晶体 稳定性 High myopia astigmatism posterior chamber type toric implantable collamer len stability
  • 相关文献

参考文献11

  • 1Shah R, Shah S, Sengupta S. Results of small incision lentieule extraction: all-in-one femtosecond laser refractive surgery[J]. Cataract Refract Surg, 2011,37(1) ; 127-137.
  • 2Yoon G, Macrae S, Williams DR, et al. Causes of spherical aberration induced by laser refractive surgery [J]. Cataract Refract Surg,2005,31(1) :127-135.
  • 3Alfonso JF, Lisa C, Fernandez-Vega-Cueto L. Comparison of visual and refractive results of torie implantable collamer lens with bioptics for myopic astigmatism[J]. Graefes Arch Clin Exp Ophthalmol, 2013,251 (3) :967-975.
  • 4Kamiy K, Shimizu K, Aizawa D, et al. One-year follow-up of posterior chamber toric phakic intraocular lens implantation for moderate to high myopic astigmatism[J]. Ophthalmology, 2010, 117(12) :2287-2294.
  • 5Sari ES, Pinero D, Kubaloglu A, et al. Toric implantable collamer lens for moderate to high myopic astigmatism: 3-year follow-up[J]. Graefes Arch Clin Exp Ophthalmol, 2013, 251 (5) : 1413-1422.
  • 6Hashemian SJ, Soleimani M, Foroutan A, et al. Toric implantable eollamer lens for high myopic astigmatism in keratoconic patients after six months[J]. Clin Exp Optom, 2013,96 (2) : 225-232.
  • 7Sarver EJ, Sanders DR. Astigmatic power calculations for intraocular lenses in the phakic and aphakic eye[J]. Refract Surg,2004,20(5) :472-477.
  • 8Hashem AN, E1 DA, Anwar HM. Axis alignment and rotational stability after implantation of the toric implantable collamer lens for myopic astigmatism[J]. Refract Surg,2009,25 (10):939-943.
  • 9Park SC, Kwun YK, Chung ES, et al. Postoperative astigmatism and axis stability after implantation of the STAAR toric implantable eollamer lens[J]. Refract Surg, 2009,25 (5) : 403-409.
  • 10Tan MC, Nah GK. Positional and rotational stability of the toric phakic intraocular lens under high +G(z) environments [J]. Aviat Space Envir Md, 2012,83 (2) : 144-147.

同被引文献47