摘要
通过介绍武汉宜家购物中心自动喷水灭火系统的设计,阐述了以购物中心为代表的大型综合建筑自动喷水灭火系统设计特点、难点及设计方法。针对不同功能的建筑部位,采用不同的灭火标准和系统,并通过多种自动喷水灭火系统的组合,满足综合建筑的自动喷水灭火系统设计要求。
Through the introduction of the sprinkler system for Inter IKEA Shopping Center in Wuhan,this paper explained the design characteristics,key points and design method of the sprinkler system in large comprehensive building including shopping mall.According to the different parts of building with various functions,different fire-fighting standards and systems should be used;through the different combination of sprinkler systems,the design requirements in comprehensive building would be satisfied.
出处
《给水排水》
CSCD
北大核心
2016年第4期68-74,共7页
Water & Wastewater Engineering
关键词
超大规模购物中心
泡沫+干式系统
湿式系统
预作用系统
窗玻璃和卷帘加密保护系统
自动消防炮灭火系统
Super shopping center
Foam-dry pipe systems
Wet pipe systems
Preaction systems
Enhanced fire-fighting system for glass windows and curtains
Automatic fire-extinguishing cannon system