期刊文献+

混凝土可泵性评价方法研究 被引量:6

Study on evaluation methods of pumpability for concrete
下载PDF
导出
摘要 传统以坍落度、压力泌水试验为代表的混凝土可泵性评价方法已难以适应现代混凝土。对现阶段国内外几种有代表性的混凝土可泵性评价方法进行了总结与分析,结果表明:混凝土可泵性评价需要多种方法相结合才全面准确,并针对不同特点的混凝土工程,提出了相应的混凝土可泵性组合评价方法。 Traditional evaluation methods for concrete pumpability,such as slump and pressure bleeding test,has been difficult to adapt to modern concrete. Several representative evaluation methods of concrete pumpability at home and abroad were summarized and analysed here,and the results showthat in order to evaluate the pump performance of concrete comprehensively and accurately,a variety of evaluation methods must be combined. For different concrete engineering with distrinct characteristics,the corresponding combined evaluation methods of concrete pumpability are put forward in the end.
作者 徐俊 许永和
出处 《混凝土》 CAS 北大核心 2016年第3期114-116,共3页 Concrete
基金 上海市科学技术委员会资助课题(14DZ2252100) 上海市国资委企业技术创新和能级提升项目(2013027) 国家"十二五"科技支撑计划资助项目(2014BAJ03B00)
关键词 现代混凝土 评价方法 评价指标 可泵性 对比分析 modern concrete evaluation method evaluation index pumpability comparative analysis
  • 相关文献

参考文献14

二级参考文献8

  • 1龚洛书.混凝土实用手册[M].北京:中国建筑工业出版社,1997,6..
  • 2JGJ/T10-95.混凝土泵送施工技术规程[S].[S].,..
  • 3任世漫,施工技术,1998年,5期
  • 4龚洛书,混凝土实用手册,1997年
  • 5赵志缙,泵送混凝土,1985年
  • 6CECS 203:2006,自密实混凝土应用技术规程[S].
  • 7钟俊宏,等.台北101大楼自充填混凝土施工案例[Z].
  • 8任世漫,陈静.特细砂高强混凝土的配制[J].施工技术,1998,27(5):17-18. 被引量:2

共引文献51