期刊文献+

液化石油气中二甲醚含量快速测定方法研究 被引量:5

Study on the Fast Quantitative Analysis of the Content of DME Adulterated in LPG
下载PDF
导出
摘要 二甲醚(DME)掺入液化石油气(LPG)中能加速储气罐橡胶密封圈的老化,存在严重安全隐患,直接危害消费者安全和利益,国家明令规定禁止向LPG中掺入二甲醚等化学品作为液化气商品出售,因此实现LPG中DME含量的快速分析极其重要。提出一种快速测定LPG中DME含量的新方法,解决了液化气成分快速测量技术难题。实验设计和制造了一套精确配制DME液化气溶液的装置和一套基于近红外光谱技术快速测定LPG的分析系统。该分析系统耐压3.5 MPa,可方便与高压钢瓶连接,实现了液化气直接快速测量。收集了市场上LPG-1(胺前液化气),LPG-2(焦化液化气),LPG-3(脱硫醇后液化气)LPG-4(沧炼催化液化气)共四种液化石油气,采集其近红外光谱作为背景子空间,采用称重法配制DME浓度范围1.0%~45.0%。采用斜投影算法从LPG溶液近红外光谱中提取出不同浓度LPG溶液中DME纯信号,使用DME纯信号强度I与浓度c建立标准曲线,其线性相关系数为0.999 4。外部验证结果表明,方法相对误差小于2.0%。该方法具有操作简单,快速、无需建模等优点。 A new analytical method of analyzing dimethyl ether(DME)content in liquefied petroleum gas(LPG)is proposed in this paper.An unsolved problem about quick detection of the composition of LPG has been settled with this method.A set of precise preparation apparatus for DME/LPG solution and a set of quickly analytical system of LPG based on near infrared technology were designed.The analytical equipment can be conveniently connected to the sampling cylinder because it can bear 3.5MPa pressure.Oblique projection algorithm was used to separate the pure spectra of DME from that of the LPG's solutions.The standard curve of the concentration of DME(c)has been built by using the Intensity(I)of pure signal of DME in the LPG solution and the concentrations.The correlation coefficient of the equation is 0.999 4.The result of external validation shows that the relative error is less than 2.0%.The new method has the advantages such as fast,easy and noneed of expensive multivariate modeling.
出处 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2016年第4期978-980,共3页 Spectroscopy and Spectral Analysis
基金 国家科技支撑计划项目(2011BAE11B01)资助
关键词 NIR 二甲醚 液化石油气 斜投影算法 Near-infrared spectroscopy Dimethyl ether Liquefied petroleum gas Oblique projection
  • 相关文献

参考文献5

  • 1Chen Z Y, Jiang L S, Jian L I, et al. Technology & Development of Chemical Industry, 2013, 42(8) : 45.
  • 2Chu X, Lu W. Electronic Instrumentation Customers, 2013, 2: 002.
  • 3He K, Qian F, Cheng H, et al. Chemometrics and Intelligent Laboratory Systems, 2015, 140 : 117.
  • 4Graham S F, Haughey S A, Ervin R M, et al. Food Chemistry, 2012, 132(3): 1614.
  • 5刘伟,赵众,袁洪福,宋春风,李效玉.光谱多元分析校正集和验证集样本分布优选方法研究[J].光谱学与光谱分析,2014,34(4):947-951. 被引量:52

二级参考文献10

  • 1Daszykowski M, Walczak B, Massart D L. Analytical Chimica Acta, 2002, 468: 91.
  • 2Gabriel G Siano, Hfictor C Goicoechea. Chemometrics and Intelligent Laboratory Systems, 2007, 88: 204.
  • 3YUANHong-fu,CHUXiao-li,TIANGao-you,etal(袁洪福,褚小立,田高友,等).StandardGuidelinesforMolecularSpectroscopyMultivariateCalibrationQuantitativeAnalysis(分析光谱多元校正定量分析通则).NationalStandard(中华人民共和国国家标准).
  • 4Kanduc K R, Zupan J, Majeen N. Chemometrics and Intelligent Laboratory Systems, 2003, 65(2): 221.
  • 5Kennard R W, Stone L A. Technometrics, 1969, 11: 137.
  • 6Snee R D. Technometries, 1977, 19(4): 415.
  • 7wuJing-zhu(吴静珠).ResearchofNIR-BasedTechnologyonAgricultureProductsDetection(农产品品质检测中的近红外光潜分析技术研究).Beijing:ChinaAgriculturalUniversity(北京:中国农业大学),2006.
  • 8Roberto Kawakami Harrop Galvno, Mdrio Cesar Ugulino Araujb, Gledson Emidio Jose, et al. Talanta, 2005, 67: 736.
  • 9Christian Hakemeyera, Ulrike Straussa, Silke Werza, et al. Talanta, 2012, 15: 12.
  • 10谢军,潘涛,陈洁梅,陈华舟,任小焕.血糖近红外光谱分析的Savitzky-Golay平滑模式与偏最小二乘法因子数的联合优选[J].分析化学,2010,38(3):342-346. 被引量:56