期刊文献+

无创正压通气中人机连接装置的技术特点 被引量:1

Technical characteristics of interfaces for noninvasive positive pressure ventilation
原文传递
导出
摘要 人机连接装置是连接呼吸机管路与患者面部,为无创正压通气(NPPV)提供气流通路的一类装置。此类装置具备一些独有的技术特点,如装置所致死腔较其内部容积明显缩小;漏气过大等因素导致人机不同步;人机不同步、装置的设计及材质欠佳等导致耐受性降低等,认识及处理不当会严重影响NPPV的顺利进行及通气效果,容易导致NPPV失败。因此,本文就装置相关技术特点作一综述。 Patient-ventilator interfaces are fixed between noninvasive ventilator and patientsr face for the application of noninvasive positive pressure ventilation (NPPV). The interfaces have some special technical characteristics, for example, the dead space is significantly smaller than the internal volume, excessive leaks and other factors lead to patient-ventilator asynchrony, and patient-ventilator asynchrony, designs and materials of interfaces will affect patient' s tolerance. Overlooking such characteristics will extremely affect the application of NPPV, and probably cause NPPV failure. Accordingly, this review summarizes the technical characteristics related to the interfaces.
出处 《国际呼吸杂志》 2016年第6期457-460,共4页 International Journal of Respiration
关键词 正压通气 人机连接装置 技术特点 Positive pressure ventilation Patient-ventilator interfaces Technical characteristics
  • 相关文献

参考文献40

  • 1Hess DR. The Growing role of noninvasive ventilation inpatients requiring prolonged mechanical ventilation [J]. RespirCare, 2012, 57(6) :900-918. DOI: 10. 4187/respcare. 01692.
  • 2Sferrazza Papa GF, Di Marco F, Akoumianaki E, et al. Recentadvances in interfaces for non-invasive ventilation : from benchstudies to practical issues [J] . Minerva Anestesiol, 2012,78(10):1146-1153.
  • 3Collaborative Research Group of Noninvasive MechanicalVentilation for Chronic Obstructive Pulmonary Disease. Earlyuse of non-invasive ,positive pressure ventilation for acuteexacerbations of chronic obstructive pulmonary disease: amulticentre randomized controlled trial [J] . Chin Med J(Engl) , 2005,118(24) : 2034-2040.
  • 4Masip J, Roque M, Sanchez B, et al. Noninvasive ventilation inacute cardiogenic pulmonary edema: systematic review andmeta-analysis[j] JAMA, 2005, 294(24) :3124-3130.
  • 5Kohnlein T, Windisch W, Kohler D, et al. Non-invasivepositive pressure ventilation for the treatment of severe stablechronic obstructive pulmonary' disease: a prospective,multicentre, randomised, controlled clinical trial [J]. LancetRespir Med, 2014,2(9): 698-705. DOI: 10. 1016/S2213-2600?14)70153-5.
  • 6Zhan Q, Sun B, Liang L, et al. Early use f noninvasive positivepressure ventilation for acute lung injury : A multicenterrandomized controlled trial [j] . Crit Care Med, 2012, 40(2):455-460. DOI: 10. 1097/CCM. 0b013e318232d75e.
  • 7Chandra D, Stamm JA, Taylor B, et al. Outcomes ofnoninvasive ventilation for acute exacerbations of chronicobstructive pulmonary disease in the United States, 1998-2008[J], Am J Respir Crit Care Med, 2012, 185 (2) : 152-159.DOI: 10.1164/rccm. 201106-10940C.
  • 8Cabrini L, Esquinas A, Pasin L, et al. An international surveyon noninvasive ventilation use for acute respiratory failure ingeneral non-monitored wards [jj ? Respir Care, 2015,60(4):586-592.DOI: 10. 4187/resp care. 03593.
  • 9Stefan MS, Shieh MS, Pekow PS, et al. Epidemiology andoutcomes of acute respiratory failure in the United States,2001 to 2009 : a national survey [J] . J Hosp Med, 2013, 8(2):76-82. DOI: 10.1002/jhm. 2004.
  • 10Walkey AJ, Wiener RS. Use of noninvasive ventilation inpatients with acute respiratory failure, 2000-2009 : apopulation-based study [J] . Ann Am Thorac Soc, 2013,10(1):10-17.DOI: 10.1513/AnnalsATS.201206-034OC.

二级参考文献13

  • 1慢性阻塞性肺疾病无创机械通气治疗研究协作组.早期应用无创正压通气治疗慢性阻塞性肺疾病急性加重期患者的多中心随机对照研究[J].中华结核和呼吸杂志,2005,28(10):680-684. 被引量:226
  • 2有创-无创序贯机械通气多中心研究协作组.以肺部感染控制窗为切换点行有创与无创序贯机械通气治疗慢性阻塞性肺疾病所致严重呼吸衰竭的随机对照研究[J].中华结核和呼吸杂志,2006,29(1):14-18. 被引量:279
  • 3British Thoracic Society Standards of Care Committee. Noninvasive ventilation in acute respiratory failure. Thorax, 2002,57 : 192-211.
  • 4Bernstein G, Knodel E, Heldt GP. Airway leak size in neonates and autocycling of three flow-triggered ventilators. Crit Care Med, 1995,23 : 1739-1744.
  • 5Mehta S, Hill NS. Noninvasive ventilation. Am J Respir Crit Care Med ,2001,163:540-577.
  • 6Mehta S, McCool FD, Hill NS. Leak compensation in positive pressure ventilators : a lung model study. Eur Respir J, 2001,17 : 259-267.
  • 7SteU IM, Paul G, Lee KC,et aL Noninvasive ventilator triggering in chronic obstructive pulmonary disease. A test lung comparison. Am J Respir Crit Care Med ,2001,164:2092-2097.
  • 8Prinianakis G, Kondili E, C, eorgopoulos D. Effects of the flow waveform method of triggering and cycling on patient-ventilator interaction during pressure support. Intensive Care Med, 2003, 29 : 1950-1959.
  • 9Imanaka H, Nishimura M, Takeuchi M, et aL Autotriggering caused by cardiogenie oscillation during flow-triggered mechanical ventilation. Crit Care Med, 2000, 28:402-407.
  • 10Hill LL, Pearl RG. Flow triggering, pressure triggering, and autotriggering during mechanical ventilation. Crit Care Med, 2000,28:579-581.

共引文献9

同被引文献10

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部