摘要 随着发电机机组向大容量方向发展,为避免机组起动过程中对电网和机组本身造成冲击,静止变频起动系统目前已开始应用于大型同步电机的变频起动领域。本文基于燃气轮机组静止变频起动系统,分析了电机转子在不安装位置传感器的情况下,如何通过电气检测方法计算转子初始位置。该方法操作简单且方便可靠,已经在动模实验平台上得到验证。 As the large-capacity generator develops, in order to avoid impact on the grid as well as the unit itself during startup, static frequency conversion system has been used in the field of frequency conversion start of large synchronous motor. Based on the static frequency conversion start system of gas turbine, this paper analyzed how to use electrical detection method to calculate the initial position of the rotor without installing the position sensor. The method is simple, convenient and reliable, which has passed validation on the dynamic simulation experiment platform.
出处 《电气技术》 2016年第3期56-59,共4页 Electrical Engineering
关键词 静止变频起动 电气检测方法 转子初始位置 static frequency conversion electrical detection method initial position of the rotor
  • 相关文献

参考文献4

二级参考文献14

  • 1PETERSSON T. StaRing of large synchronous motor using static frequency converter[J]. IEEE Trans PAS, 1972, 91(1): 172- 179.
  • 2PENEDER F. Static equipment for starting pumped-storage plants[J]. Synchronous Condensers and Gas Turbine Sets. Brown Boveri Review, 1974,61(9/10):440-447.
  • 3LUO Y L. Study of the variable frequency start-up process of pumped storage machines.Pt Ⅰ , Pt Ⅱ [A]. ICEM '93 [C]. Wuhan, 1993. 153-164.
  • 4LIU T H, LIN C Y. Modeling and performance of a static frequency converter starting a 300 MVA synchronous machine [J]. Electric Power Systems Research, 1996,(37):45-53.
  • 5CHIANG Juag-chen,WU Chi-jui.Mitigation of harmonic disturbance at pumped storage power station with static frequency converter[J].IEEE Transactions on Energy Conversion,1997,12(3):232-240.
  • 6MAGSAYSAY Greg,SCHUETTE Thomas,FOSTIAK Russ.J.Use of a static frequency converter for rapid load response in pumped-storage plants[J].IEEE Transactions on Energy Conversion,1995,10(4):694-699.
  • 7LIU Tian-hua,LIN Chih-ying,YANG Jin-shyr,CHANG Wen-yao.Modeling and harmonics elimination for a static frequency converter driving a 300 MVA synchronous machine[R].Power Research Institute,National Taiwan Institute of Technology,1996.
  • 8田立军,陆于平,陈珩.抽水蓄能电动发电机启动过程数字仿真[J].电力系统自动化,1997,21(7):38-41. 被引量:17
  • 9杨波,李官军,胡旭光,刘华栋,冯炜.基于RTDS的抽水蓄能机组静止变频器启动技术研究[J].电气传动,2010,40(5):20-23. 被引量:15
  • 10李官军,杨波,陶以彬,王德顺,俞斌,桑丙玉.抽水蓄能机组静止变频器起动控制系统半实物仿真[J].电机与控制应用,2011,38(1):52-56. 被引量:5

共引文献25

同被引文献52

引证文献5

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部