摘要 针对强水敏油藏储层特征,从防膨率、腐蚀率、破碎率和配伍性实验筛选了四种防膨剂,现场应用结果可知单一加入防膨剂难以满足油田需要。通过正交试验方法优化筛选出防膨效果最佳的配方:2.5%KCl+0.8%FA-367+1%ZJ-1+1%XH-F3,其防膨率达到86.06%。动态防膨实验表明岩心渗透率的伤害率从37.6%下降到8.21%,防膨作用明显。现场应用实验表明,该防膨体系对黏土稳定性较好,能很好满足强水敏油藏注水开发需要。 According to the characteristics of strong water sensitivity reservoir,an optimum anti- swelling formulation was proposed in the paper. Based on anti- swelling rate,corrosion rate,crushing rate and compatibility,four anti- swelling agents were elected. The experimental result showed that it was difficult to meet the requirement of anti- swelling in oilfield by single anti- swelling agent. So an optimum anti- swelling formulation was screened out through orthogonal experiment, containing2. 5% KCl,0. 8% FA- 367,1% ZJ- 1 and 1% XH- F3.The anti- swelling rate of this formulation was up to 86. 06%.Moreover,the dynamic anti- swelling experiment was used to measure the varieties of the core damage rate. It suggested that core permeability damage rate was 37. 6% without the anti-swelling system but decreased to 8. 21% with the anti- swelling system and the anti- swelling effect was obvious. Field application proved that this anti- swelling system was beneficial to stabilize the clay. All these evidences showed that this formulation was well suitable for injecting water development in strong water sensitivity oilfield.
出处 《钻采工艺》 CAS 北大核心 2016年第2期108-110,6,共3页 Drilling & Production Technology
关键词 强水敏油田 防膨剂 筛选 现场应用 strong water sensitivity oilfield anti-swelling agent screening field application
  • 相关文献

参考文献5

二级参考文献13

共引文献20

同被引文献73

引证文献6

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部