摘要 目前海外项目已占具了国内电力勘察设计行业中不小的份额,提高专业设计人员运用国际标准的能力,做好技术储备,应对海外项目的各种变化,是一项迫在眉睫的工作。美国工程建设标准在越南、印尼等国家得到比较广泛的应用。针对油罐区总平面布置,从五个方面比较了中美规范的差异,得出油罐区的防火设计规范,我国标准基本上都高于美国规范的标准的结论,可供相关设计人员参考。 At present the overseas projects have been accounted for a large proportion of domestic electric power survey and design industry. It is an urgent work for professional designer to improve the ability to use international standards,to prepare good technical reserves,to deal with all kinds of changes. American engineering construction standards have been widely applied in Vietnam,Indonesia and other countries. In this paper,the general layout of oil tank area design compares the five aspects of the differences between Chinese and American Standard Codes for fire prevention design of oil tank area. We conclade the Chinese standards are generally stricter than the American Standards which can be used for reference for designers.
作者 赖琦
出处 《南方能源建设》 2016年第1期101-104,共4页 Southern Energy Construction
关键词 总体布置 油罐区防火 general layout tank farm fireproofing
  • 相关文献

参考文献8

  • 1GB50016-2004,建筑设计防火规范[S].
  • 2GB50660-2011大中型火力发电厂设计规范[S].2011.
  • 3GB 50074-2014,石油库设计规范[S].
  • 4火力发电厂与变电站设计防火规范[S].(GB50229-2006).
  • 5NFPA 30-2015, Flammable and Combustible Liquid Code [S].
  • 6NFPA 853-2015, Standard for the Installation of Stationary Fuel Cell Power System [ S ].
  • 7NFPA 5000-2015, Building Construction and Safety Code [S].
  • 8NFPA59A-2016, Standard for the Production, Storage, and Handling of Liquefied Natural Gas (LNG) [ S ].

共引文献111

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部