摘要 电流互感器的选择要根据系统短路电流、互感器实际二次负荷、保护整定值和灵敏度要求进行综合考虑。按最大短路电流不超过电流互感器准确限值电流的原则选择电流互感器额定一次电流,可能导致保护整定困难;按设备额定容量选择电流互感器额定一次电流,则可能导致互感器过饱和引起保护拒动。为解决上述问题,提出了按保护整定计算确定站用变压器电流互感器参数的方法和过程。 The set of current transformer should be considered comprehensively according to the system short circuit current,actual secondary load of mutual inductor,setting value of protection,requirement of sensitivity.To set the rated primary current of current transformer according to the principle of maximum short-circuit current should be no more than the accurate limit current value of current transformer,it would lead to difficulties for the value setting of protection.To set the rated primary current of current transformer according to rated capacity of equipment would lead to protection failure caused by oversaturation of current transformer.To solve the problems above,a method that set the parameters of current transformer based on setting value of protection is proposed.
作者 姜百超
出处 《供用电》 2016年第2期69-72,共4页 Distribution & Utilization
关键词 站用变压器 电流互感器 参数选择 保护整定 station transformer current transformer parameter setting protection setting
  • 相关文献

参考文献5

  • 1DL/T8662004,电流互感器和电压互感器选择及计算导则[S].
  • 2DL/T5155.2002220kV~500kV变电站所用电设计技术规程[s].
  • 3袁季修.电流互感器和电压互感器[M].北京.中国电力出版社,2011.
  • 4袁季修,盛和乐,秦应力,沙玉洲,安作平,冀有党,陶惠良,李和,何赞峰.中压系统保护用电流互感器参数选择方法[J].电力自动化设备,2007,27(2):1-5. 被引量:16
  • 5GB/T142852006继电保护和安全自动装置技术规程[S].北京:中国标准出版社,2006.

二级参考文献3

  • 1国家发展和改革委员会.DI/T 866—2004电流互感器和电压互感器选择及计算导则[S].北京:中国电力出版社,2004.
  • 2国家经济贸易委员会.DL/T 5153—2002火力发电厂厂用电设计技术规定[S].北京:中国电力出版社,2002.
  • 3盛和乐,袁季修,秦应力,等.中压电流互感器及继电保护装置联合试验研究报告[R].北京:国电华北电力设计院工程有限公司,北京四方继保自动化有限公司.大连;大连第一互感器厂,2004.