期刊文献+

装车鹤管高液位报警器故障分析与对策 被引量:1

FAILURE ANALYSIS ON THE HIGH LIQUID LEVEL ALARM ON LOADING ARM AND THE COUNTERMEASURES
下载PDF
导出
摘要 高液位控制系统是轻油装车鹤管的配套设施,作为防溢流设备的高液位报警器在成品油装车安全生产中发挥着重大作用。受工作环境的影响,现用高液位报警器在使用过程中故障率高、使用寿命短,给轻质油槽车装车安全带来很大危害,增加了运行成本。分析了高液位报警器产生故障的原因,提出了改进措施,对高液位报警器探头在使用过程中稳定性差、光纤易损坏、不耐腐蚀以及抗挤压性能差等问题,有针对性地提出了相关设计改进建议。 High liquid level control system is an ancillary facility of light oil loading arm.And as the overflow preventing device,high liquid level alarm plays a major role in safety loading of refined oil.However,affected by work environment,current high liquid level alarm has high failure rate and short service life when using.And this brings great harm to the safety of light oil tank lorry load and increases the operation cost.This article analyzes the failure causes of high liquid level alarm and puts forward the improvement measures.Moreover,aiming at the problems of poor stability,easy for optical fiber damage,noncorrosion resistance and poor anti-extrusion performance of the high liquid level alarm probe in the progress of using,the article brings forward targeted improvement suggestions for relevant design.
作者 邓迪 张宇松
出处 《石油化工安全环保技术》 CAS 2016年第1期35-37,6,共3页 Petrochemical Safety and Environmental Protection Technology
关键词 高液位报警器 小鹤管 故障分析 改进措施 High liquid level alarm Small crane tube Failure analysis Improvement measures
  • 相关文献

参考文献3

二级参考文献10

  • 1张桂菊,于清旭.一种非本征F-P腔型光纤传感器的研究[J].仪器仪表学报,2004,25(z1):253-254. 被引量:3
  • 2刘跃辉,张旭苹,董玉明.光纤压力传感器[J].光电子技术,2005,25(2):124-132. 被引量:20
  • 3陶卫,赵辉,刘伟文.新型反射式闪耀光栅楔形平板[J].光电工程,2005,32(8):40-43. 被引量:4
  • 4HUANG S C,LIN TSAI M T,et al. Fiber optic in-line distributed sensor for detection and localization of the pipeline leaks. Sensors and Actuators A 135 ( 2007 ) 570 - 579.
  • 5LIN C I, TSENG F G. A micro Fabry-Perot sensor for nano-lateral displacement sensing with enhanced sensitivity and pressure resistance. Sensoes ang Actuators A 114 ( 2004 ) 163 - 170.
  • 6AREF S H,LATIFIH,ZIBAII M L,et al. Fiber optic Fabry-Perot pressure sensor with low sensitivity to temperature changes for downhole application. Optics Communications 269 ( 2007 ) 322 - 330.
  • 7XU J C, WANG X W, KRISTE L. Cooper etc. Miniature Temperature- Insensitive Fabry-Perot Fiber-Optic Pressure Sensor. IEEE Photonics Technology Letters,2006,18 (10).
  • 8Sun Dexing,Cheng Shouliu,Pan Chao Jin Henghuan. Proceedings of SPIE the International Society for Optical Engineering .
  • 9Katsuharu Iwamot. Appliance . 1992
  • 10陈实英,郭文庆,何春生.光纤液位传感器的研究[J].传感器技术,2000,19(5):47-48. 被引量:6