摘要
制定了测定镀镍溶液中硼酸的新方法。用草酸钾掩蔽镀液中的镍离子和镀液中铁杂质及锌杂质离子,用氟化钠掩蔽铝杂质离子,用甘露醇与硼酸反应生成酸性较强的配合酸,用酚酞作指示剂,以氢氧化钠滴定法测定配合酸。实验表明,本法的相对平均偏差为0.2%,回收率为99.62%,精密度和回收率都较高。
A novel method of measuring boric acid in a nickel plating bath was established. The nickel ion,iron impurity,and zinc impurity in the plating bath were masked by potassium oxalate. The aluminum impurity was masked using sodium fluoride. The boric acid reacted with D-mannitol to produce a stronger complex acid which had stronger acidity than boric acid. The complex acid was titrated by utilizing sodium hydroxide standard titrating solution with phenothalin as indicator. The experiments showed that the relative average deviation of analysis results was 0. 2% and the percent recovery was 99. 62%.
出处
《电镀与精饰》
CAS
北大核心
2016年第4期44-46,共3页
Plating & Finishing
关键词
镀镍溶液
硼酸
分析方法
铝离子
氟化钠
掩蔽剂
nickel plating solution
boric acid
analysis method
aluminum ion
sodium fluoride
masking agent