期刊文献+

Increasing energy relaxation time of superconducting qubits with nonmagnetic infrared filter and shield

Increasing energy relaxation time of superconducting qubits with nonmagnetic infrared filter and shield
下载PDF
导出
摘要 One of the primary origins of the energy relaxation in superconducting qubits is the quasiparticle loss. The quasiparticles can be excited remarkably by infrared radiation. In order to minimize the density of quasiparticle and increase the qubit relaxation time, we design and fabricate the infrared filter and shield for superconducting qubits. In comparison with previous filters and shields, a nonmagnetic dielectric is used as the infrared absorbing material, greatly suppressing the background magnetic fluctuations. The filters can be made to impedance-match with other microwave devices. Using the as-fabricated infrared filter and shield, we increased the relaxation time of a transmon qubit from 519 ns to 1125 ns. One of the primary origins of the energy relaxation in superconducting qubits is the quasiparticle loss. The quasiparticles can be excited remarkably by infrared radiation. In order to minimize the density of quasiparticle and increase the qubit relaxation time, we design and fabricate the infrared filter and shield for superconducting qubits. In comparison with previous filters and shields, a nonmagnetic dielectric is used as the infrared absorbing material, greatly suppressing the background magnetic fluctuations. The filters can be made to impedance-match with other microwave devices. Using the as-fabricated infrared filter and shield, we increased the relaxation time of a transmon qubit from 519 ns to 1125 ns.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第5期457-460,共4页 中国物理B(英文版)
基金 Project supported by the National Natural Science Foundation of China(Grant Nos.91321310,11274156,11474152,11474153,61521001,and 11504165) the State Key Program for Basic Research of China(Grant Nos.2011CB922104 and 2011CBA00205)
关键词 qubit relaxation superconducting qubit infrared filter infrared shield qubit relaxation superconducting qubit infrared filter infrared shield
  • 相关文献

参考文献20

  • 1Clarke J and Wilhelm F K 2008 Nature 453 1031.
  • 2Devoret M H and Schoelkopf R J 2013 Science 339 1169.
  • 3Zhong Y, Li C, Wang H and Chen Y 2013 Chin. Phys. B 22 110313.
  • 4Zhu S and Wang Z 2005 Physics 34 0.
  • 5Dial O, McClure D T, Poletto S, Gambetta J M, Abraham D W, Chow J M and Steffen M 2015 arXiv: 1509.03859vl [quant-ph].
  • 6Martinis J M, Cooper K B, McDermott R, Steffen M, Ansmann M, Os- born K D, Cicak K, Oh S, Pappas D P, Simmonds R W and Yu C C 2005 Phys. Rev. Lett. 95 210503.
  • 7Martinis J M, Ansmann M and Aumentado J 2009 Phys. Rev. Lett. 103 097002.
  • 8Shaw M D, Lutchyn R M, Delsing P and Echternach P M 2008 Phys. Rev. B 78 024503.
  • 9Barends R, Wenner J, Lenander M, Chen Y, Bialczak R C, Kelly J, Lucero E, O'Malley P, Mariantoni M, Sank D, Wang H, White T C, Yin Y, Zhao J, Cleland A N, Martinis J M and Baselmans J J A 2011 Appl. Phys. Lett. 99 113507.
  • 10de Visser P J, Baselmans J J A, Diener P, Yates S J C, Endo A and Klapwijk T M 2011 Phys. Rev. Lett. 106 167004.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部