摘要 利用HNO_3-H_2O_2密闭微波消解-ICP-MS同时测定电解金属锰阳极液中12种元素(Fe、Pb、Ni、Zn、Sr、Cr、Ti、Co、Cu、Cd、Sb、Ge),内标铟(In)和铋(Bi)消除基体效应和仪器信号漂移。结果表明,该方法具有较强的抗干扰性(相关系数r〉0.9999),加标回收率均为93.93%~106.16%,相对标准偏差RSD〈3.5%。该方法操作简单、快速,适用于电解金属锰阳极液中多种元素的同时检测。 To simultaneously determine 12 elements in the anolyte of electrolytic manganese metal,including Fe,Pb,Ni,Zn,Sr,Cr,Ti,Co,Cu,Cd,Sb,Ge,a closed microwave digestion-inductively coupled plasma-mass spectrometry( ICP-MS) in HNO_3-H_2O_2 system is adopted. The internal standard elements,indium( In) and bismuth( Bi),are used to correct matrix effects and instrument signal drift. The results indicate that the method of ICP-MS in HNO_3-H_2O_2 system has many advantages,such as a strong anti-interference performance with the correlation coefficient over 0. 999 9,high recovery ratio of standard addition( 93. 93%- 106. 16%) and low relative standard deviation( less than 3. 5%).Moreover,this method is simple and fast,which is suitbable to analyze multiple elements in the anolyte of electrolytic manganese metal.
出处 《现代化工》 CAS CSCD 北大核心 2016年第4期179-181,共3页 Modern Chemical Industry
基金 国家科技支撑计划环境基准与风险评估国家重点实验室自主研究课题(SKLECRA201555 SKLECRA201514)
关键词 ICP-MS 密闭微波消解 电解金属锰 阳极液 元素 ICP-MS closed microwave digestion electrolytic manganese metal anolyte element