摘要
通过分析某核电厂附加柴油发电机厂房建筑防火设计中存在的问题,从防火布置、防火分区、安全疏散、油罐间设计等方面,进行了建筑防火优化设计,降低了火灾危害的发生,提高了核电厂的安全性能。
Through analyzing building fire protection design problems of the nuclear power plant adding diesel generator workshop,starting from aspects of fire protection layout,fire protection distribution,safety evacuation and oil tank design,the paper carries out the building fire protection design,which reduces the fire hazards and improves the nuclear power safety performance.
出处
《山西建筑》
2016年第11期14-15,共2页
Shanxi Architecture
关键词
发电机厂房
防火设计
安全疏散
油罐间
electric generator workshop
fire protection design
safety evacuation
oil tank house