摘要
根据监测数据,综合分析确定自然发火危险区,通过均压调整系统、封堵漏风通道和注浆消除高温点的方法,实现快速灭火目的。
According to the monitoring data, determine spontaneous combustion danger zone by a comprehensive analysis, use the average pressure adjustment system, plug leakage channel and grouting pressure equalizing eliminate temperature point methods, to achieve rapid fire.
出处
《山东煤炭科技》
2016年第4期51-53,共3页
Shandong Coal Science and Technology
关键词
均压
注浆
灭火
average pressure
grouting
fire fighting