摘要 受高低温环境温度的影响,电能表现场校验仪的现场测量精度可能会显著下降,无法做出正确检定。通过对电能表现场校验仪的测量原理和硬件结构的深入分析,揭示了高低温环境对校验仪测量精度的影响机理,提出了一种基于关键元器件温漂系数综合优化的改进方案,并研制了样机。试验结果表明。在-30~55℃,样机均能够保持0.05S级准确度,平均温度系数不超过0.08‰/℃。 Influenced by high or low environment temperature, measurement accuracy of watt-hour-meter calibrator may decrease significantly and unable to calibrate correctly. Based on measuring principle and hardware structure of watt-hour-meter field calibrator, mechanism of environment temperature influence on measurement accuracy is analyzed. A novel hardware improvement scheme is proposed based on temperature coefficients optimization of key electrunical components. The experimental results on prototype equipment show that average temperature coefficient is less than 0.08‰/℃. The prototype meets 0.05S measuring precision in temperature ranging from -30 ℃ to 55 ℃.
出处 《中国电力》 CSCD 北大核心 2016年第4期27-31,共5页 Electric Power
基金 国家自然科学基金资助项目(51207020) 国家电网公司科技项目(5210EF140008)~~
关键词 电能表 校验仪 现场 温度 干扰 watt-hour meter calibrator field temperature interference
  • 相关文献

参考文献6

二级参考文献16

  • 1赵玉富,叶妙元,贺志容,杨先明,叶继红.用Rogowski线圈测量微小电流[J].高电压技术,2004,30(7):12-13. 被引量:15
  • 2李维波,毛承雄,余岳辉,陆继明.罗氏线圈在高速大功率电流检测系统中的特性研究[J].电工技术学报,2006,21(6):49-53. 被引量:14
  • 3.电子式电能表JJG596-1999[S].中国计量出版社,..
  • 4.交流电能表检定装置JJG597-89[S].中国计量出版社,..
  • 5.MDP303型电能表检定装置校验仪说明书[Z].郑州三晖电气有限公司,..
  • 6.电子式电能表JJG596-1999[S].中国计量出版社,..
  • 7.交流电能表检定装置JJG597-89[S].中国计量出版社,..
  • 8.MDP303型电能表检定装置校验仪说明书[Z].郑州三晖电气有限公司,..
  • 9DL/T 585-95电子式标准电能表技术条件[Z].
  • 10JJG 597-2005交流电能表检定装置[Z].