摘要
受高低温环境温度的影响,电能表现场校验仪的现场测量精度可能会显著下降,无法做出正确检定。通过对电能表现场校验仪的测量原理和硬件结构的深入分析,揭示了高低温环境对校验仪测量精度的影响机理,提出了一种基于关键元器件温漂系数综合优化的改进方案,并研制了样机。试验结果表明。在-30~55℃,样机均能够保持0.05S级准确度,平均温度系数不超过0.08‰/℃。
Influenced by high or low environment temperature, measurement accuracy of watt-hour-meter calibrator may decrease significantly and unable to calibrate correctly. Based on measuring principle and hardware structure of watt-hour-meter field calibrator, mechanism of environment temperature influence on measurement accuracy is analyzed. A novel hardware improvement scheme is proposed based on temperature coefficients optimization of key electrunical components. The experimental results on prototype equipment show that average temperature coefficient is less than 0.08‰/℃. The prototype meets 0.05S measuring precision in temperature ranging from -30 ℃ to 55 ℃.
出处
《中国电力》
CSCD
北大核心
2016年第4期27-31,共5页
Electric Power
基金
国家自然科学基金资助项目(51207020)
国家电网公司科技项目(5210EF140008)~~
关键词
电能表
校验仪
现场
温度
干扰
watt-hour meter
calibrator
field
temperature
interference