摘要
某项目工程总建筑面积大,消防给水系统统一规划分部实施,有效利用资源,节约投资。其工程采用双首层建筑布局,消防规范无明确条款参照,后通过消防专家评审会评审,为设计提供了参考依据。工程中管线走廊通过合理布置,在不设吊顶的情况下也不失美观,节约造价,具有一定的参考价值。
The total floorage of the project is quite massive, so the firefighting system is uniformly designed but separately implemented for effective resource utilization and investment conservation. It adopts double first floors planning, so there is no clear firefighting terms for references, which, with the evaluation by firefighting experts, are offered for the design. The pipeline corridor in the project, with reasonable layout, is not ugly with no furred ceiling and can save cost. It can offer some references.
出处
《重庆建筑》
2016年第4期21-23,共3页
Chongqing Architecture
关键词
双首层
给水
排水
常高压消防给水系统
管线综合布局
double first floors
water supply
water drainage
water supply system of ordinary high pressure
comprehensive pipeline layout