摘要
合成辣椒素可用于非致命性武器和弹药、镇痛剂、驱虫剂、无公害的农药和船舶防污驱虫涂料等。水分和挥发分含量会影响到合成辣椒素的质量和使用性能,准确测定其数值是非常必要的。比较了不同测定方法和测定条件对水分和挥发分测定结果的影响,确定了较好的测定方法和测定条件。
Synthetic capsaicin can be used for non-lethal weapons and anamunition, anodyne, anthehnintic, non environmental pollution pesticide and antilbuling repellent paint. The moisture and volatiles may influence the quality and perlbrmance of the synthetic capsaicin. So, it is necessary to accurately determinate its content. Through comparison the influence of different determination nlethods and conditions, the preferable method and condition is given.
出处
《广东化工》
CAS
2016年第8期183-184,共2页
Guangdong Chemical Industry
关键词
合成辣椒素
水分和挥发分
真空烘箱法
烘箱法
syntheticcapsaicin: moisture and volatiles: vacuum oven method: ovenmethod