摘要 自动喷水灭火系统可以有效控制和扑灭初期火灾,因此整个系统的响应时间成了灭火的关键。利用Monte Carlo方法进行随机取样模拟实验,建立了包含喷头响应时间指数、火灾增长因子、火源与喷头径向间距、火源与顶棚垂直间距等影响因素的喷头响应时间模型,并通过大量数据分析得到了响应时间的分布特性。结果表明,响应时间基本符合对数正态分布。响应时间与喷头响应时间指数线性相关,随火灾增长因子的增大而缩短,随径向间距的增大而增长,随着垂直间距的增大先是略为下降而后上升。 Sprinkler system can effectively control and extinguish initial fire,therefore the response time of the whole system becomes the significant element to the fire extinction. A random sampling simulation experiment was proceeded in accordance with Monte-Carlo method,and a sprinkler response time model was built which includes the influencing factors such as sprinkler response time index,fire growth rate,radial spacing between fire seat and sprinkler,vertical interval between fire seat and the roof. Finally a distribution character of response time was obtained through a mass of data analysis. The results indicated that the response time basically conforms to the lognormal distribution. The response time has a linear correlation with the sprinkler's response time index: it decrease with the increase of the fire growth rate,and increase with growth of the radial spacing,and decrease slightly and then increase again with the increase of the vertical interval.
出处 《科学技术与工程》 北大核心 2016年第11期79-85,共7页 Science Technology and Engineering
基金 国家自然科学基金(51404215) 中国博士后科学基金(2014M550386 2015T80781)资助
关键词 蒙特卡洛方法 响应时间 响应时间指数(RTI) 火灾增长因子 Monte Carlo method response time response time index(RTI) fire growth rate
  • 相关文献

参考文献18

二级参考文献29

  • 1张村峰,霍然,李元洲.火灾中闭式喷头响应特性研究[J].中国工程科学,2005,7(11):55-59. 被引量:7
  • 2隋晓琳,李剑峰,刘茂,陈晨.Monte-Carlo模拟在确定可用安全疏散时间中的应用[J].中国公共安全(学术版),2007(1):41-44. 被引量:6
  • 3Bukowshi R W. Fire Hazard Analysis [A]. In: Fire Protection Handbook [M]. 19th ed. Quincy, MA: National Protection Association,.2003 Section 3 Chapter 7.
  • 4Budnick E K, Evans D D, Nelson H E. Simplified Fire Growth Calculations[A] . In: Fire Protection Handbook [M]. 19th ed. Quincy, MA: National Protection Association,2003. Section 3 Chapter 9.
  • 5Gupta A K. Modeling the response of sprinklers in compartment fires[J]. Fire and Materials, 2001, 25: 117 -121.
  • 6Chow W K. Performance of sprinkler in atrium [J]. Journal of Fire Sciences, 1996,14:467-488.
  • 7Ruffino P, diMarzo M. The effect of evaporative cooling on the activation time of sprinklers[A]. Fire Safety Science-Proceedings Seventh International Symposium[C],2003:481-492.
  • 8P. G. Holborn, P. F. Nolan, J. Colt. An Analysis of Fire Size, Fire Growth Rates and Times Between Events Using Data from Fire Investigations [J]. Fire Safety Journal, 2004,39: 481- 524.
  • 9S.Ulrich, A. Laguecir and S. Stoll. Complex formation between a nanoparticle and a weak polyelectrolyte chain: Monte Carlo simulations. Journal of Nanoparticle Research, 2004,6: 595 - 603
  • 10H. Zhou and D. W. Smith. Kinetics of ozone disinfection in a CSTB system. J. Envir. Engng, ASCE. 1994, 120(4):841 - 858

共引文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部