摘要 目的建立高效液相色谱(HPLC)和电感耦合等离子体质谱(ICP-MS)联用技术检测水中三价铬Cr(Ⅲ)和六价铬Cr(Ⅵ)的分析方法。方法样品以缓冲溶液(75 m M HNO3和0.6 m M EDTA的水溶液,氨水调p H=7)配制,75 m M HNO_3(氨水调p H=7)为流动相分离两种价态的铬。结果 Cr(Ⅲ)和Cr(Ⅵ)的方法检出限均为0.5 ng/m L,线性范围均为1.5~100 ng/m L,加标回收率和精密度均满足分析要求。结论建立的HPLC-ICP-MS检测水中Cr(Ⅲ)和Cr(Ⅵ)的方法,检出限为0.5 ng/m L,方法简单准确,适用于水中Cr(Ⅲ)和Cr(Ⅵ)的检测,并为建立生物样本如血液和尿液中Cr(Ⅲ)与Cr(Ⅵ)的检测方法建立基础。 Objective To establish a high performance liquid chromatography-inductively coupled plasma mass spectrometry method for the determination of Cr(Ⅲ) and Cr(Ⅵ) in water. Method Samples were prepared with buffer solution containing75 m M HNO_3 and 0.6 m M EDTA(p H=7). The mobile phase was 75 m M HNO_3(p H=7). Results The detection limits of Cr(Ⅲ) and Cr( Ⅵ) were 0.5 ng/m L, and the linear ranges were 1.5 ~100 ng/m L. Conclusion The method was proved to be accurate and reliable for the determination of Cr(Ⅲ) and Cr(Ⅵ) in water.
出处 《中国司法鉴定》 2016年第2期31-35,共5页 Chinese Journal of Forensic Sciences
基金 国家自然科学基金项目(81302613) 上海市技术标准专项(13DZ0503001) 中央级科研院所社会公益研究资助项目(GY1102) 上海市法医学重点实验室资助项目(14DZ2270800)
关键词 形态分析 高效液相色谱-电感耦合等离子质谱法 Cr species analysis high performance liquid chromatography-inductively coupled plasma mass spectrometry(HPLC-ICP-MS) water
  • 相关文献

参考文献10

  • 1李建文,黄坚.铬的形态分析研究与展望[J].冶金分析,2006,26(5):38-43. 被引量:21
  • 2V. G6mez,M.P. Callo.Chromium determination and speciation since 2000[J]. Trends in Analytical Chemistry,2006,25 (10):1006-1015.
  • 3F. S6by,S. Charles,M. Gafean. Chromium speciation by hyphenation of high-performance liquid chromatography to inductively coupled plasma-mass spectrometry study of the influence of interfering ions[J]. J. Anal_ At. Spectrom., 2003,18 ( 11 ) : 1386-1390.
  • 4杨冬梅.铬与人体健康[J].科技创新导报,2008,5(30):179-179. 被引量:18
  • 5Shizhong Chen, Li Zhu, Dengbo Lu, et al.Separation and chromium speciation by single-wall carbon nanotubes mi crocolumn and inductively coupled plasma mass spectrometry[J]. Microchim Acta,2010,169(1-2) : 123-128.
  • 6Huajian Wang,Xianmei Du,Meng Wang,et al.Using ion pair reversed-phase HPLC ICP-MS to simultaneously determine Cr( IU ) and Cr(VI ) in urine of chromate workers[J]. Talanta, 2010, (81) : 1856-1860.
  • 7王骏,胡梅,张卉,张喜琦,玄国东,祝建华.液相色谱-质谱法对饮用水中六价铬的测定[J].分析测试学报,2009,28(12):1468-1470. 被引量:29
  • 8Liyan Xing. Diane Beauchemin.Chromium speciation at trace level in potable water using hyphenated ion exchange chromatography and inductively coupled plasma mass spectrometry with collision/reaction interface[J]. Journal of Analytical Atomic Spectrometry, 2010, (25) : 1046-1055.
  • 9张冀飞,高欣,杨晓兵.高效液相色谱-电感耦合等离子体质谱联用测定儿童玩具中痕量铬(Ⅲ)与铬(Ⅵ)[J].分析测试学报,2015,34(2):232-236. 被引量:15
  • 10黎飞,王扬,张成,黄城,叶磊海.HPLC/ICP-MS法测定水质中Cr(Ⅲ)和Cr(Ⅵ)的研究[J].宁波大学学报(理工版),2012,25(3):13-16. 被引量:15