摘要
为解决岸桥经常出现因松缆造成电缆损坏或拉断的情况,分析电缆驱动使用情况及故障原因,并根据磁滞耦合器驱动的工作原理,制定出电缆松缆双重保护方案,以提高系统工作的可靠性。
In order to solve the quay crane cable damage or breakage caused by the cable loose, the driving condition and the fault of the cable are analyzed. According to the principle of the hysteresis coupling drive device, the double-protection method for the cable loose is presented to improve the reliability of the system.
出处
《港口科技》
2016年第4期31-34,共4页
Port Science & Technology
关键词
港口
岸桥
电缆卷筒
驱动装置
磁滞联轴器
port
quay crane
cable reel
drive device
hysteresis coupling