矿用高压开关电器短路开断与关合试验电源

Power source of short circuit breaking and making test for mining high-voltage switch
下载PDF
导出
摘要 针对国内冲击发电机性能参数不足,以国外冲击发电机作为试验电源,建立基于直接试验法的矿用高压开关电器短路开断与关合试验系统,提出了一种新的技术解决方案。仿真试验结果表明,该方案满足综合性煤矿高压电气实验室建设项目技术指标和试验标准要求,为大容量开断与关合试验系统设计和建造提供一种技术思路。 In order to improve the performance parameters of domestic short circuit generators,we took a foreign short circuit generator as test power source,established a short circuit breaking and making test system on the basis of direct test method,and put forward a new technical scheme.Simulation results show that the scheme can meet the technical need and the testing criteria of the comprehensive mine electrical laboratory.The scheme provides a solving idea of constructing system for large capacity breaking test.
作者 陈钊
出处 《重庆大学学报(自然科学版)》 EI CAS CSCD 北大核心 2016年第2期58-63,106,共7页 Journal of Chongqing University
基金 矿用新装备新材料安全准入分析验证中心实验室建设项目(2014744)~~
关键词 短路 开断与关合 发电机 高电压 大电流 试验标准 short circuit breaking and making generator high voltage strong current testing criterion
  • 相关文献

参考文献16

  • 1机械工业部.JB/T8739矿用隔爆型高压配电装置[S].北京:机械科学研究院,1998:2.
  • 2国家质量监督检验检疫总局,国家标准化管理委员会.GB/T156-2007标准电压[S].北京:中国标准出版社,2007:3.
  • 3国家质量监督检验检疫总局,国家标准化管理委员会.GB/T12326-2008电能质量电压波动和闪变[S].北京:中国标准出版社,2008:2.
  • 4郝明剑.大容量冲击发电机的开发成果[J].上海大中型电机,2009(1):1-3. 被引量:4
  • 5Yoda H, Fujita M, Nakamura E, et al. The world's largest class 8,880MVA short circuit generator[C]//2002 IEEE Power Engineering Society Summer Meeting, July 22-25, Chicago, IL, USA.[S.L.]:IEEE,2002,2:688-693.
  • 6张亮,刘大鹏,邵桂兰,宋晓东.大中容量短路试验发电机主要设计特点[J].大电机技术,2011(3):28-30. 被引量:5
  • 7汪海波,万德春,洪深.大容量冲击发电机短路电流衰减特性研究[J].江苏电机工程,2013,32(5):26-29. 被引量:9
  • 8李重光.国外大容量冲击发电机概况[J].高压电器,1975(4):55-64.
  • 9王征庆.大容量试验短路发电机[J].高压电器,1988(3):27-35.
  • 10臧尔诚.冲击发电机选型初探[J].大电机技术,1986(5):10-15.