期刊文献+

表观弥散系数影像自动融合指导无框架立体定向颅内穿刺活检 被引量:1

Automated apparent diffusion coefficient imaging guided frameless stereotactic biopsy of intracranial lesions: A preliminary experience
下载PDF
导出
摘要 目的探讨基于表观弥散系数(apparent diffusion coefficient,ADC)影像自动融合指导的无框架立体定向活检技术在颅内病变活检中的应用价值。方法连续选取我院2015年1-7月因临床诊断困难需行活检的脑肿瘤病例16例,其中男性9例,女性7例;年龄9~78岁,平均46岁,均进行ADC影像自动融合的无框架立体定向活检术。结果 16例均成功实施活检,ADC图标记靶点平均每例耗时2 min 7 s,单个靶点平均耗时1 min 53 s。患者均获得明确病理诊断,诊断阳性率为100%。所有病例穿刺后靶点均未发现血肿,术后无新发神经功能障碍。结论基于ADC影像自动融合指导的无框架立体定向活检技术在颅内病变活检中具有较高的病理诊断阳性率,标记靶点简便快捷,在提高手术准确性、安全性方面有一定优势。 Objective To evaluate the feasibility and accuracy of automated apparent diffusion coefficient imaging guided frameless stereotactic biopsy of intracranial lesions. Methods From January to July in 2015, a consecutive series of 16 patients with intracranial lesions diagnosed by biopsy were prospectively enrolled. The cohort consisted of 9 males and 7 females with a mean age of 46 years(ranged from 9 to 78 years). All patients had undergone apparent diffusion coefficient(ADC) imaging-guided biopsy. Results ADC imaging-guided biopsy was successfully implemented in all cases. It took 2 minutes 7 seconds for single patient and 1 minute 53 seconds for single target to delineate targets using ADC imaging. All cases got a clear pathological diagnosis with the diagnosis positive rate of 100%. Intracerebral hematoma and worse neurological deficits was not found after surgery. Conclusion ADC imaging-guided frameless stereotactic biopsy of intracranial lesions has a high pathological diagnosis positive rate. The target can be selected efficiently according to the ADC imaging of the lesion with high accuracy and safety.
出处 《解放军医学院学报》 CAS 2016年第4期308-311,共4页 Academic Journal of Chinese PLA Medical School
基金 国家自然科学基金项目(81271515)~~
关键词 表观弥散系数 神经导航技术 立体定位技术 活组织检查 apparent diffusion coefficient neuronavigation stereotaxic techniques biopsy
  • 相关文献

参考文献18

  • 1朱伟杰,陈晓雷,张家墅,李防晔,吴东东,张猛,张华平,宋志军,许百男.氢质子磁共振波谱影像自动融合指导无框架立体定向颅内病变活检[J].中华外科杂志,2014,52(4):280-284. 被引量:11
  • 2李昉晔,陈晓雷,何婷婷,张家墅,宋志军,李晋江,郑刚,胡深,张挺,许百男.基于代谢影像的多模态功能神经导航在无框架立体定向穿刺活检术中的应用[J].中华外科杂志,2013,51(4):358-361. 被引量:18
  • 3Essig M, Anzalone N, Combs SE, et al. Mr imaging of neoplastic central nervous system lesions : review and recommendations for current practice [ J ] . AJNR Am J Neuroradiol, 2012, 33 ( 5 ) : 803-817.
  • 4Mabray MC, Cohen BA, Villanueva-Meyer JE, et al. Performance of apparent diffusion coefficient values and conventional MRI features in differentiating tumefactive demyelinating lesions from primary brain neoplasms [ J ] . AJR Am J Roentgenol, 2015, 205 ( 5 ) : 1075- 1085.
  • 5Sehwyzer L, Berberat J, Remonda L, et al. Susceptibility changes in meningiomas influence the apparent diffusion coefficient in diffusion- weighted MRI [ J ] . J Neuroradiol, 2015, 42 ( 6 ) : 332-337.
  • 6Dom f nguez-Pinilla N, Mart i nez de Arag 6 n A, Di 6 guez Tapias S, et al. Evaluating the apparent diffusion coefficient in MRI studies as a means of determining paediatric brain tumour stages [ J/OL ] . http : //www.elsevier.es/en/linksolver/ft/pii/S0213-4853 ( 14 ) 00265-5.
  • 7Chen X, Xu BN, Meng X, et al. Dual-room 1.5-T intraoperative magnetic resonance imaging suite with a movable magnet : implementation and preliminary experience [ j ] . Neurosurg Rev, 2012, 35 ( 1 ) : 95-109.
  • 8张家墅,陈晓雷,李昉晔,李晋江,郑刚,张挺,胡深,许百男.新型无框架立体定向系统VarioGuide在颅内病变穿刺活检中的初步应用[J].中华医学杂志,2012,92(21):1468-1471. 被引量:13
  • 9Chernov M, Muragaki Y, Taira T, et al. 1H-MRS-guided stereotactic brain biopsy [ J ] . Stereotact Funct Neurosurg, 2012, 90 ( 1 ) : 63- 65.
  • 10Frati A, Pichierri A, Bastianello S, et al. Frameless stereotactic cerebral biopsy : our experience in 296 cases [ J ] . Stereotact Funct Neurosurg, 2011, 89 (4): 254-245.

二级参考文献48

  • 1Hall WA, Liu H, Truwit CL. Navigus trajectory guide. Neurosurgery, 2000, 46: 502-504.
  • 2Woodworth GF, McGirt MJ, Samdani A, et al. Frameless imageguided stereotactic brain biopsy procedure: Diagnostic yield, surgical morbidity, and comparison with the frame-based technique. J Neurosurg, 2006, 104: 233-237.
  • 3Dorward NL, Paleologos TS, Alberti O, et al. The advantages of frameless stereotactic biopsy over frame-based biopsy. Br J Neurosurg, 2002, 16: 110-118.
  • 4Paleologos TS, Dorward NL, Wadley JP, et al. Clinical validation of true frameless stereotactic biopsy: analysis of the first 125 consecutive cases. Neurosurgery, 2001,49: 830-835.
  • 5Smith JS, Quinones-Hinojosa A, Barbaro NM, et al. Frame-based stereotaetic biopsy remains an important diagnostic tool with distinct advantages over frameless stereotactic biopsy. J Neurooncol, 2005, 73 : 173-179.
  • 6Galloway RL Jr, Maciunas R J, Latimer JW. The accuracies of four stereotactic frame systems: an independent assessment. Biomed Instrum Technol, 1991, 25 : 457-460.
  • 7Maciunas R J, Galloway RL Jr, Latimer JW. The application accuracy of stereotactic frames. Neurosurgery, 1994, 35 : 682- 695.
  • 8Quinones-Hinojosa A, Ware ML, Sanai N, et al. Assessment of image guided accuracy in a skull model: comparison of frameless stereotaxy techniques vs. frame-based localization. J Neurooneol, 2006, 76: 65-70.
  • 9Ringel F, Ingerl D, Ott S, et al. VarioGuide: a new frameless image-guided stereotactic system-accuracy study and clinical assessment. Neurosurgery, 2009, 64: 365-371.
  • 10Nimsky C, Kuhnt D, Ganslandt O, et al. Muhimodal navigation integrated with imaging. Acta Neurochir Suppl, 2011, 109: 207- 214.

共引文献41

同被引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部