摘要 介绍美国A核电厂十年大修中的整体密封性试验流程,包括其所采用的标准、测量系统及试验方案,并对试验结果及方案的合理性进行了分析。 The paper described the process of integrated leakage rate test(ILRT) during the 10 year outage of U.S. A nuclear power plant, including test criteria, test equipment and test project, and gave a brief analysis of test result and test process.
出处 《能源与节能》 2016年第5期85-87,100,共4页 Energy and Energy Conservation
关键词 安全壳 整体密封性试验 试验工艺 containment ILRT experiment technology
  • 相关文献

参考文献3

  • 1American Nuclear Society.ANSI/ANS-56.8-1994 Containment System Leakage Testing Requirement[S].Kensington Avenue: American Nuclear Society, 1994.
  • 2Bechtel Corporation.BN-TOP-1 Testing Criteria for Integr- ated Leakage Rate Testing of Primary Containment Structures for Nuclear Power Plant [ S ].San Francisco: Bechtel Corporat-ion, 1972.
  • 3中冶建筑研究总院有限公司,北京,台核技术发展有限责任公司.NBT20018-2010核电厂安全壳密封性试验[S].北京:国家能源局.2010.