股静脉自外前方完全覆盖股动脉变异1例 被引量:1

Femoral vein co vering femoral artery from the outer front:a case report
原文传递
导出
摘要 患者男,64岁,因肾功能不全于2015年4月27日在天津医科大学总医院肾脏内科拟行股静脉置管及血液透析。行股静脉穿刺术前,自右腹股沟中点稍下方股动脉投影点以触诊法寻找股动脉,但未触及明显搏动感;改变触诊部位,约在腹股沟内侧1/4处时方可触及较弱的搏动感。同时发现左侧股动脉搏动点位于左腹股沟中点稍下方,且搏动感明显强于右侧。采用 Terason t3000TM超声系统(泰圣公司,美国)进一步定位血管,在腹股沟以下22 mm 位置探测时,右股动脉明显偏内侧且位置偏深,中心点距离体表22 mm;而右股静脉中心点位于右股动脉中心点外前方,且完全覆盖于右股动脉之上,在超声探头轻微压力下,右股静脉塌陷至内径达20 mm时其内侧缘略超出右股动脉内侧缘3 mm。左股动脉中心点位于左股静脉中心点外前方,距离体表18 mmnbsp;(图1)。
出处 《中华解剖与临床杂志》 2016年第2期183-184,共2页 Chinese Journal of Anatomy and Clinics
基金 国家自然科学基金(81200534)
关键词 股动脉 股静脉 遗传变异 Femoral artery Femoral vein Geneticvariation
  • 相关文献

参考文献6

  • 1Hopkins JW, Warkentine F, Gracely E, et al. The anatomic relationship between the common femoral artery and common femoral vein in frog leg position versus straight leg position in pediatric patients[J]. Acad Emerg Med, 2009, 16(7): 579-584.
  • 2Warkentine FH, Clyde Pierce M, Lorenz D, et al. The anatomic relationship of femoral vein to femoral artery in euvolemic pediatric patients by ultrasonography: implications for pediatric femoral central venous access[J]. Acad Emerg Med, 2008, 15(5): 426-430.
  • 3Hind D, Calvert N, McWilliams R, et al. Ultrasonic locating devices for central venous cannulation: meta-analysis[J]. BMJ, 2003, 327(7411): 361.
  • 4陆利冲,汪小海,李浩,郑曼.超声下股静脉与股动脉间解剖关系及其影响因素的研究[J].临床麻醉学杂志,2011,27(9):851-853. 被引量:19
  • 5Egan G, Healy D, O′Neill H, et al. Ultrasound guidance for difficult peripheral venous access: systematic review and meta-analysis[J]. Emerg Med Jo, 2013, 30(7): 521-526.
  • 6Randall C, Schmeiser E, Fiers E, et al. Ultrasound investigation of leg position to enhance femoral vein exposure for cannulation[J]. J Emerg Med, 2014, 47(2): 176-181.

二级参考文献9

  • 1Aouad MT, Kanazi GE, Abdallah FW, et al. Femoral vein cannulation performed by residents: a comparison between ul- trasound-guided and landmark technique in infants and chil- dren undergoing cardiac surgery. Anesth Analg, 2010, 111: 724- 728.
  • 2Balls A, LoVecchio F, Kroeger A, et al. Ultrasound guidance for central venous catheter placement: results from the Cen- tral Line Emergency Access Registry Database. Am J Emerg Med, 2010, 28:561-567.
  • 3lwashima S, Ishikawa T, Ohzeki T. Ultrasound guided versus landmark-guided femoral vein access in pediatric cardiac cathe- terization. Pediatr Cardiol, 2008, 29:339-342.
  • 4Hopkins JW, Warkentine F, Gracely E, et al. The anatomic relationship between the common femoral artery and common femoral vein in frog leg position versus straight leg position in pediatric patients. Acad Emerg Med, 2009,16:579 -584.
  • 5Duperier T, Mosenthal A, Swan KG, et al. Acute complica- tions associated with greenfield filter insertion in high-risk trauma patients. J Trauma, 2003, 54:545-549.
  • 6Schnyder G, Sawhney N, Whisenant B, et al. Common femo- ral artery anatomy is influenced by demographics and comor- bidity:implications for cardiac and peripheral invasive studies. Catheter Cardiovasc Interv, 2001, 53 : 289-295.
  • 7Schummer W, Schummer C, Rose N, et al. Mechanical complica- tions and malpositions of central venous cannulations by experi- enced operators, A prospective study of 1794 catheterizations in critically ill patients, Intensive Care Med, 2007, 33 : 1055-1059.
  • 8Shih C J,Lai T K. Fuzzy weighting optimization with several objective function in structual design[J]. Computer & Structures,1994,52(5):32-35.
  • 9张满和.股静脉穿刺置管误入腹腔一例[J].临床麻醉学杂志,2009,25(11):1012-1012. 被引量:2

共引文献18

同被引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部