期刊文献+

保护用超大电流互感器的屏蔽方案分析 被引量:1

The analysis on shielding methods of protective heavy current transformer
下载PDF
导出
摘要 文中对保护用超大电流互感器的屏蔽方法进行了对比分析,针对平衡绕组常用的两种连接方式——"反极性串"和"四段全并",先利用有限元数值计算软件ANSYS仿真计算出各绕组的电感和彼此间的互感,进而通过分析其线性电路模型,求解各绕组的电流及测量误差;通过比较两种屏蔽方案对杂散磁通的屏蔽效果和发热量,给出了优选建议。 The paper compares two shielding methods of protective heavy current transformer,when shielding coils are in reverse-polarity series connection and in parallel connection,and calculates the winding inductance and mutual inductance between each otherwith finite element software ANSYS,and analyses the linear circuit modelto obtain the current of coils and measurement error. Then,the paper compares the shielding effects and heat radiation,to make the judgment that which method is better.
出处 《电测与仪表》 北大核心 2016年第8期90-94,共5页 Electrical Measurement & Instrumentation
关键词 保护用电流互感器 屏蔽 测量误差 发热量 protective current transformer shielding measurement error heat radiation
  • 相关文献

参考文献10

  • 1B.B.阿法纳两耶夫电流互感器[M].北京:机械工业出版社1989:1-12.
  • 2GB1208-2006电流互感器[S].北京:国家质量监督检验检疫总局,2006.
  • 3DL/T866-2004.电流互感器和电压互感器选择及计算导则[S].[S].,..
  • 4Pfuntner, R.A. The Accuracy of Current Transformer Adjacent to High-Current Busses[J]. AIEE Trans. , 1951(70) : 1656-1662.
  • 5Seely. S. Effect of Stray Flux On Curren! Transformers[J]. Journal of Science & Technology. 1970, 37 ( 3 ) : 115-120.
  • 6Forrest, H. E. Influence of Leakage Flux Under Various Conditions [J]. Electrical Review. 1948, (9) : 51-54.
  • 7Seely. S. Shielding Electrical Apparatus Frum Stray Flux[J]. Electri- cal Review. 1964, 175(11 ) : 390-399.
  • 8Seely. S. Design of eun'enl transtormers tbr the currents[J]. Electrical Review. 1970, (5) : 833-835.
  • 9屈凯峰,赵伟,江波,杨鹏,黄松岭.大电流互感器内磁屏蔽方案的性能比较[J].高电压技术,2009,35(9):2096-2101. 被引量:6
  • 10屈凯峰,赵伟,江波,杨鹏,黄松岭.大电流互感器内磁屏蔽方案的方向性研究[J].变压器,2009,46(9):27-31. 被引量:3

二级参考文献20

  • 1许加柱,罗隆福,李季,尚荣艳.大电流互感器试验时的电磁耦合场分析[J].高压电器,2004,40(6):446-448. 被引量:3
  • 2许加柱,罗隆福,尚荣艳,李季.大电流互感器的屏蔽绕组电流分析与优化[J].高电压技术,2005,31(1):33-34. 被引量:4
  • 3许加柱,罗隆福,李季.基于场路耦合法的大电流互感器屏蔽绕组分析[J].中国电机工程学报,2006,26(23):167-172. 被引量:18
  • 4Seely S. Shielding electrical apparatus from stray flux[J]. Elec. Rev., 1964,175(11) :390-399.
  • 5Seely S. Effect of stray flux on current transformers[J]. J. Sci. Tech., 1970,37(3):115-120.
  • 6Braun A. Determination of current transformer errors at primary currents up to 100000 A[J]. IEEE Trans on Instrumentation and Measurement, 1977, 26(3): 263-267.
  • 7Pfuntner R A. The accuracy of current transformers adjacent to heavy current buses[J]. AIEE Trans, 1951, 70: 1656-1661.
  • 8Imamura M, Nakahara M, Yamaguehi T, et al. Analysis of magnetic fields due to three-phase bus bar currents for the design of an optical current transformer[J]. IEEE Trans on Magnetics, 1998, 34(4): 2274-2279.
  • 9Seely S. Shielding electrical apparatus from stray flux[J]. Electrical Review, 1964, 175(11): 390-399.
  • 10Seely S. Effect of stray flux on current transformers[J]. Journal of Science & Technology, 1970, 37(3) : 115-120.

共引文献66

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部