期刊文献+

浅层河流、湖泊地表水源热泵供冷负荷与水体匹配性分析 被引量:1

The Matching-Relationship Between Cold Load and Water Volume of Surface Water Heat Pump
下载PDF
导出
摘要 根据热量守恒定律建立地表水源热泵水温模型,结合南京地区工程实例,以地表水周最大温升≤1℃为标准,建立供冷负荷与水体匹配性关系,并分析不同水体表面积(1000m2~10000m2)、不同水深(2m、2.5m和3m)时的对应关系。同理,得到长江流域地区4个典型城市供冷负荷与水体匹配性关系,从而对地表水源热泵设计提供参考。 Water temperature model of surface water heat pump(SWHP) was established by the law of conservation of energy in this paper. Combining with an actual project in Nanjing, the relationship between cold load and water volume of SWHP was set up based on a criterion that was environmental quality standards for surface water, and the influence factors of water surface area and depth was analyzed. In addition, the relationship of 4 typical cities in the Changjiang River Region was also established. Therefore, it could provide reference for the design of SWHP.
出处 《制冷与空调(四川)》 2016年第2期191-195,共5页 Refrigeration and Air Conditioning
关键词 地表水源热泵 水温 供冷负荷 水体 匹配性 SWHP water temperature cold load water volume matching-relationship