摘要
分析了核电站用气动平板闸阀开启超时或无法开启等故障的原因,提出了合理的处理方案。
As for the Pneumatic Parallel Gate Valve Failed to open in Nuclear Power Plant, the possible causes are explored and itemized. The root cause and proposed solution are provided.
出处
《阀门》
2016年第2期43-45,共3页
VALVE MAGAZINE