摘要
本文详细介绍了华能玉环电厂1000MW超超临界机组最为典型的一次滑停,并通过对玉环电厂历次滑停进行分析,总结出1000MW超超临界机组滑参数停机操作思路和特点,给出了注意事项,为今后同类型1000MW超超临界机组的深度滑参数停机提供了参考。
This article introduces a typical sliding-parameter shutdown process of 1000MW ultra-supercritical unit in Huaneng Yuhuan Power Plant.By analyzing the previous sliding-parameter shutdown process,operational logic,experience of 1000MW ultra-supercritical unit and some operational attentions are given.The results provide reference for proper treatment on deep sliding-parameter shutdown of the same type 1000MW ultra-supercritical units.
出处
《电力技术》
2010年第Z2期56-61,共6页
Electric Power Standarization & Construction Cost Control Information
关键词
1000MW超超临界
滑参数停机
无电泵滑停
1000MW ultra-supercritical
sliding-parameter shutdown
without starting motor-driven feed water pump