摘要
应用胎心电子监护仪腹壁监测法对134例孕妇进行常规NST测试,对测试图形进行评分及分组,同时对新生儿出生Apgar评分及预后等方面进行观察。结果:反应型组108例,新生儿窒息率10.3%,窒息复苏较易,预后良好。无反应型组4例,新生儿窒息率100%,窒息复苏较难,预后差。可疑型组22例,新生儿窒息率31.8%,预后介于前两组之间。提示NST测试能反应胎儿宫内情况及胎儿储备能力,根据NST测试评分结合具体情况,给予积极处理,对降低围产儿死亡率有实用价值。
pregnant women were under rutine NST test with electromonitor to observe the heart rate of fetuses. The diagram showed that among 108 responsive cases the rate of neonate asphyxiation is 10.38% with easy resuscitation and good prognosis;in the four nonresponsive cases the rate of neonate asphyxiation is 100% with slow resuscitation and poor prognosis;of 22 doubtful cases the rate is 31.8%.The NST test is of great value in reflecting the state of the fetus in uterus and in providing the doctors with information for emergency treatment of perinatals.
关键词
NST
胎心率
胎儿预后
NST
Heart rate of fetuses
Fetuses prognosis