摘要
文章详细分析了造成某循环流化床锅炉主汽温度偏低的原因,采取的相应治理方案,及系统改造后使用效果等,通过本文的讨论,为锅炉运行中出现的异常现象分析判断及处理提供了参考。
The article analyzes in detail the reason of low main steam temperature ina circulating fluidized bed boiler. We discussed the control scheme of the default, and the utilization effect after reforming the system. By the introduction, a reference can be provided for judgement and analysis of anomalies in the operation of fluidized bed boilers.
出处
《电气技术》
2016年第4期149-151,共3页
Electrical Engineering
关键词
锅炉
主汽温度偏低
治理方案
fluidized bed boiler
low main steam temperature
harness