摘要
针对带股道分割的车站,当机车反向进入股道时,存在机车越过分割绝缘后收不到码的问题,从电路原理上进行了分析,并提出了对应的解决方案,对ZPW-2000A车站正线电码化电路的设计、施工及故障分析处理有很好的参考价值。
As for station with track cut,the locomotive could not receive the code after it runs over the cut insulation point when a locomotive is pulling into the track in the reversal direction.An analysis of circuit theory is given and corresponding solution is proposed,offering good references for the design,construction,and fault analysis and treatment of main line code circuit of ZPW-2000 Astation.