摘要 目的:探讨人体成分分析仪(BCM)监测在改善维持性血液透析(MHD)患者透析低血压中的作用。方法:透析低血压患者24人,女6名,男18名,平均年龄(67±8.7)岁,进行BCM监测,对患者的干体重进行重新评估和调整,比较BCM监测前后1月的低血压发生率和平均动脉压的变化。结果:BCM监测前平均干体重(58.7±7.9)kg,BCM监测后平均干体重(61.4±8.1)kg。BCM监测前透析低血压发生率为40%,而监测后的发生率明显降低为15%。BCM监测并上调干体重后透析低血压发生率明显减少(P<0.001),BCM监测并上调干体重后的透前平均动脉压较前无明显改变(P>0.05)。结论:BCM监测在改善MHD患者透析低血压的同时不增加患者水钠潴留,不升高透前血压,能较快速并准确的调节患者干体重。 Objective:To investigate the role of human body composition monitor(BCM) monitoring in the improvement of hemodialysis hypotension in patients with maintenance hemodialysis(MHD).Methods:Patients with dialysis hypotension 24,female6,male 18,average age(67±8.7)years,BCM monitor,of patients with dry weight to re evaluate and adjust,BCM monitor before and after 1 month of hypotension occurred rate and mean arterial pressure changes.Results:BCM monitoring the average dry weight(58.7±7.9)kg,BCM monitoring after the average dry weight(61.4±8.1)kg.BCM monitoring the incidence of dialysis hypotension was40%,and the incidence rate was 15%.BCM monitoring and up regulation of dry weight after dialysis hypotension incidence rate was significantly reduced(P<0.001),BCM monitoring and up to the dry weight after the pre average arterial pressure compared with the previous no significant change(P>0.05).Conclusion:BCM monitoring in the MHD patients with dialysis hypotension without increase in patients with water and sodium retention,does not increase the blood pressure,can be more rapid and accurate adjustment of the patient's dry weight.
出处 《中国医药导刊》 2016年第1期28-29,31,共3页 Chinese Journal of Medicinal Guide
关键词 】人体成分分析仪 低血压 平均动脉压【 Body composition monitor(BCM) Hypotension Mean arterial pressure
  • 相关文献

参考文献10

二级参考文献30

  • 1王凌航,王梅.生物电阻抗分析法在评价血液透析患者干体重中的应用[J].国外医学(移植与血液净化分册),2004,2(6):7-11. 被引量:6
  • 2王凌航,左力,王梅.生物电阻抗频谱分析法评估血液透析患者干体重[J].肾脏病与透析肾移植杂志,2005,14(3):245-248. 被引量:14
  • 3左力,王梅,魏弘,冯丽丽.血液透析患者体液分布异常及透析对体液分布的影响[J].北京大学学报(医学版),2005,37(5):467-470. 被引量:16
  • 4Chongthanakorn K, Tiranathanagul K, Susantitaphong P, et al. Effective determination of dry weight by intradialytic bioimpedance analysis in hemodialysis[J]. Blood Purif, 2009,27 (3) :235-241.
  • 5Earthman C, Traughber D, Dobratz J, et al. Bioimpedanee speclroscopy for clinical assessment of fluid distribution and body cell mass[J]. Nutr Clin Pract, 2007,22 (4) :389-405.
  • 6Tattersall J. Bioimpedance analysis in dialysis: state of the art and what we can expect[J]. Blood Purif,2009,27(1):70-74.
  • 7Kouw PM,Olthof CG,ter Wee PM,et al. Assessment of postdialysis dry weight: an application of the conductivity measurement method[J]. Kidney Int, 1992,41 (2) : 440-444.
  • 8Chamney PW,Kramer M, Rode C, et al. A new technique for establishing dry weight in hemodialysis patients via whole body bioimpedance[J]. Kidney Int, 2002,61 (6): 2250-2258.
  • 9Chen YC,Chen HH, Yeh JC,et al. Adjusting dry weight by extracellular volume and body composition in hemodialysis patients[J]. Nephron, 2002,92( 1 ) : 91-96.
  • 10Foley RN, Herzog CA, Collins AJ. Blood pressure and longterm morality in United States hemodialysis patients: USRDS Waves 3 and 4 study. Kidney Int, 2002, 62:1784-1790.?A